NOT INTENDED TO BE USED IN MEDICAL APPPLICATIONS OR USED ON HUMANS
Verbalizes/Displays Analog Inputs and TC input
Scaling Analog Inputs
2 Alarm Outputs in Three Different Formats
User Friendly PC Interface Allows User to Configure and Program the Unit
Alarm Output with Adjustable Deadband
Color Change LED Display
商品説明
The UV1000-PM series has been discontinued. You can contact our Sales Department to inquire about any remaining stock.
The new OMEGASEZ® UV1000-PM universal
verbalizer is an innovative panel
meter that can verbalize and display
process signals 0 to 10 Vdc, 0 to
20 mA or 4 to 20 mA, and Type J, K,
T, and R thermocouple signals. You
can configure/program the
verbalizer through the friendly PC
user interface software to specify
the input range, display decimal
point, analog input scaling, audible
engineering unit, and high/low alarm
set point. Select from over 100
engineering units while configuring
the verbalizer. The front buttons
allows the user to select different
inputs, command/continuous talk,
and adjust volume. The UV1000-PM
is a creative solution for process
monitoring almost any type of
measurement with speech/
display/alarming.
SPECIFICATIONS Display Range: -999 to 9999 counts (highest display resolution mode -9.99 to 9.999, Automatically shifts the decimal point right or left depending on the process value of the meter) Verbalize (Speech) Range: ±9999 counts (highest speech resolution mode -9999.999 to 9999.999 counts) Command/Continuous Talk: Command/continuous speech mode selection from the button Volume Control: Set via front buttons keypad, 8 levels at 4 dB intervals Color Change LED Display: Three color change LED display; GREEN (normal operation condition), AMBER (in TC open or overrange condition) and Red (in alarm condition) Display Decimal Points Auto Shifting: Automatically shifts the decimal point right or left depending on the process value of the meter on the LED display within your selected decimal point Relay Outputs: 2 Form C (SPDT) relays, 250 Vac or 30 Vdc @ 3A (resistive load) Power Input: 90 to 240 Vac, 50 to 400 Hz 110 to 375 Vdc, equivalent voltage PC User Interface Software Features: – Selectable talking interval, 0 to 120 sec – Selectable decimal point – Adjustable input offset – High and low alarm settings – Analog input scaling – Change engineering unit-over 100 engineering unit selections – Selectable alarm output dead band Selectable Alarm Deadband: Range 0 to 999 Maximum Recommended Wire Size: 18 AWG Inductive Loads: To prolong relay contact life and suppress interference, it is a recommended engineering practice to use a snubber circuit, such as OMEGA's CNQUENCHARC Input Select Indication: Green LED Alarm Indication: Flash red LED, LED display color changing Speech Sampling Rate: 8 KHz Speaker: Built-in and external speaker, 8 Ω Operating Ambient Temperature: 0 to 50°C (32 to 122°F) Operating Relative Humidity: 0 to 95% RH (non-condensing) Dimensions: 131 L x 96 W x 48 mm D (5.13 x 3.78 x 1.89") Panel Cutout Size:1⁄8 DIN Weight: 250 g (0.55 lb)
NOT INTENDED TO BE USED IN MEDICAL APPPLICATIONS OR USED ON HUMANS
注: Comes complete with operator’s manual, external speaker, and CD with configuration program.
We noticed you are from the US. Visit your local site for regional offers and live support.