フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Conductivity Transmitters Using 4-Ring Technology - Discontinued

CDTX1200 Series

 | CDTX1200 Series

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE
  • The CDTX1200 Series 4-Ring Potentiometric Conductivity Probe is Virtually Immune to Contamination by Unclean Solutions (This Allows the Transmitter to Operate at Peak Performance at all Times)
  • Temperature Effects are Compensated for by the Built-In Temperature Sensor on the Probe and the Transmitter’s ATC Circuitry with a ß of 2%
  • Direct Connection of the Probe to the Transmitter Assures a Positive Electrical Connection with no Signal Loss Over Long Distances
  • Two Versions are Available, CDTX1200 without an LCD, and the LCD Version, CDTX1200-D, Allows Easy Verification and Monitoring of Measured Values, and is Easier to Calibrate and Maintain
  • The CDTX1200 Series is for In-Line Applications and Should Be Used in Conjunction with the CDE-1201 In-Line Probe or CDE-1202 Tank Probe with External Threads

商品説明

The CDTX1200 series has been discontinued. Please see the CDTX-111/ CDTX-112 as a possible alternative or contact our Flow Engineering department.

CONDUCTIVITY, 4-RING TECHNOLOGY

The CDTX1200 series conductivity transmitters use top of-the-line, 4-Ring Potentiometric probes. As opposed to the more widely used 2-Ring Amperometric method, the 4-Ring Potentiometric method provides the highest accuracy and repeatability attainable. When measuring liquids that have a high conductivity, the 2- Ring system is susceptible to polarization. This condition makes it exceptionally difficult to obtain measurements with any accuracy. The polarization is directly related to the electrode’s current load, and will cause a considerable, non-linear drop in the voltage. As a result, the solution around the electrode simulates a low conductivity condition.

4-Ring electrodes eliminate the polarization effect by splitting the four rings into 2 current electrodes and 2 voltage electrodes. When placed in a conductive liquid, the 2 current electrodes take the alternating voltage and create a current. This alternating current produces a Buffer Field from which polarization is absent. The voltage is then measured in this field assuring no altered readings.

Voltage electrodes carry very little current. This allows the electrodes to be arranged in a manner where the current electrodes, which are the most susceptible to polarization, are placed where they cannot affect the voltage electrodes.

Consequently, the Buffer Field is large enough for the voltage electrodes to take accurate readings without being effected by polarization.

The wide range of OMEGA conductivity probes includes models for industrial applications. Flow-thru and dip versions are available. In particular, the latest addition to this family are probes with 1/2" and 3/4" external thread for mounting on commercial pipe tees.

Some new conductivity probes combine the proven 4-ring potentiometric method of measuring conductivity with platinum sensors. The universally acclaimed 4-ring method provides a more stable measurement over a wider range. The probe does not suffer polarization, nor does it need frequent calibration or cell changes. The 4-pin CDE-1201 is a molded conductivity probe with pipe threads at both ends. The housing is fiber-reinforced polypropylene and can work with pressures up to 5 bar (72.5 psi) and temperatures as high as 80°C (176°F).

These probes combine the proven 4-ring potentiometric method with platinum





Model No. Range Description
CDTX12010.0 - 199.9 mS/cmConductivity Transmitter
CDTX1201-D0.0 - 199.9 mS/cmConductivity Transmitter with Display
CDTX12020.0 - 19.99 mS/cmConductivity Transmitter
CDTX1202-D0.0 - 19.99 mS/cmConductivity Transmitter with Display
CDTX12030.0 - 1999 µS/cmConductivity Transmitter
CDTX1203-D0.0 - 1999 µS/cmConductivity Transmitter with Display
CDTX12040.0 - 199.9 µS/cmConductivity Transmitter
CDTX1204-D0.0 - 199.9 µS/cmConductivity Transmitter with Display
CDE-1201In-Line 1" NPT Polypropylene Conductivity Probe
CDE-1202Submersible Platinum Conductivity Probe
CDS-450450 microSiemen Conductivity Standard, 1 QT
CDS-15001500 microSiemen Conductivity Standard, 1 QT
CDS-45004500 microSiemen Conductivity Standard, 1 QT
PHA-50Loop Isolator

Please download specification page for complete list of available models.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
  
CDTX1201-D
お問い合せ下さい   
納期: 
 
 
0.0 - 199.9 mS/cm Conductivity Transmitter with Display
  
CDTX1202-D
お問い合せ下さい   
納期: 
 
 
0.0 - 19.99 mS/cm Conductivity Transmitter with Display
Accessories
Click to expand/minimize a list of what others bought with theCDSA-450
CDSA-450
¥3,830 (税込)
(税抜価格 ¥3,482)
納期: 2 週間
 
— 450 microSiemen Conductivity Standard, 1 QT
Click to expand/minimize a list of what others bought with theCDSA-1500
CDSA-1500
¥3,830 (税込)
(税抜価格 ¥3,482)
納期: 2 週間
 
— 1500 microSiemen Conductivity Standard, 1 QT
Click to expand/minimize a list of what others bought with theCDSA-4500
CDSA-4500
¥4,047 (税込)
(税抜価格 ¥3,679)
納期: 2 週間
 
— 4500 microSiemen Conductivity Standard, 1 QT
Click to expand/minimize a list of what others bought with theCDSA-4500
CDSA-4500
¥4,047 (税込)
(税抜価格 ¥3,679)
納期: 2 週間
 
— 4500 microSiemen Conductivity Standard, 1 QT
Click to expand/minimize a list of what others bought with theU24Y175
U24Y175
お問い合せ下さい   
納期: 
 
 
24Vdc, 175 mA Power Supply
Click to expand/minimize a list of what others bought with theTX4-100
TX4-100
¥10,603 (税込)
(税抜価格 ¥9,639)
納期: 2 週間
 
30.5 m (100') spool of 4 Conductor Wire
注: Comes complete with operator’s manual.
 
We noticed you are from the US. Visit your local site for regional offers and live support.