フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Constant Wattage Heat Cable

CWM

Constant Wattage Heat Cable | CWM

Constant Wattage Heat Cable

スクロールダウンし、全ラインアップをご覧ください

  • Constant Output
  • Cut to Any Length
  • Lower Installation Costs
  • Flexible
ケーブルヒータ - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

OMEGALUX™ CWM (Constant Wattage Medium Temperature) heating cable is the ideal answer to those pipe tracing situations which require higher temperatures for process maintenance as well as freeze protection. No matter what length of cable is needed, wattage (or heat) produced by each foot of cable remains unchanged.

Caution and Warning!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.



Standard Construction
A. Buss wires. Twin 12 AWG copper buss wires provide reliable, consistent electrical current.
B. Buss wire insulation. 11 mil FEP jacket protects and electrically insulates buss wires.
C. Inner sheath. This insulation jacket holds the two buss wires together and provides the wrapping surface for the nichrome heating wire.
D. Nichrome wire. The nichrome resistance heating wire is the heating component of the cable.
E. Jacket. Flame-retardant insulation jacket is made from FEP material which protects heating cable and assures long service life. This material is also highly corrosion resistant.
F. Metal braid. Plated copper braid covering the jacket provides a positive ground path.
G. Optional fluoropolymer overjacket. FEP jacket provides protection from most aqueous and chemically corrosive solutions. Add suffix “-CT” to model number.

Output Tinned Copper Braid (-C) FEP Overcoat (-CT)
and Tinned Copper Overbraid
Module
Length
in (mm)
Max
Circuit
Length
feet (m)
Watts/
Foot
Volts Model
No.
Weight
lb.(kg)/
1000'
Model
Number
Weight
lb.(kg)/
1000'
4
4
120
240
CWM4-1C
CWM4-2C
96 (43.5)
96 (43.5)
CWM4-1CT
CWM4-2CT
110 (49.9)
110 (49.9)
18 (457)
30 (762)
350 (106.6)
700 (213.3)
8
8
8
120
240
480
CWM8-1C
CWM8-2C
CWM8-4C
96 (43.5)
96 (43.5)
96 (43.5)
CWM8-1CT
CWM8-2CT
CWM8-4CT
110 (49.9)
110 (49.9)
110 (49.9)
18 (457)
24 (610)
37 (940)
245 (74.6)
475 (144.7)
950 (289.5)
12
12
12
120
240
480
CWM12-1C
CWM12-2C
CWM12-4C
96 (43.5)
96 (43.5)
96 (43.5)
CWM12-1CT
CWM12-2CT
CWM12-4CT
110 (49.9)
110 (49.9)
110 (49.9)
12 (305)
24 (610)
30 (762)
200 (60.9)
400 (121.9)
800 (243.8)
Minimum length of heating cable is 25 ft. See Pages B-24 to B-28 for heat cable accessories and controls.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
Prices below are per foot
CWM4-1CT
¥5,231 (税込)
(税抜価格 ¥4,755)
納期: 2 週間
 
Constant wattage heat cable,4 watts/ft, 120 volt, with FEP overcoat and tinned copper overbraid
CWM8-2CT
¥3,966 (税込)
(税抜価格 ¥3,605)
納期: 6 週間
 
Constant wattage heat cable,8 watts/ft, 240 volt, with FEP overcoat and tinned copper overbraid
CWM12-4CT
¥3,966 (税込)
(税抜価格 ¥3,605)
納期: 6 週間
 
Constant wattage heat cable,12 watts/ft, 480 volt, with FEP overcoat and tinned copper overbraid

クイックオーダー

部品番号
注文数
部品番号
注文数


注: *Prices above are price per foot.

Steam Cleaning: CWM can withstand 200°C (392°F), 150 psig steam purging of process piping when not energized. Third Party Approvals: See page B-22. Circuit Breaker Selection: To determine the circuit breaker size required divide the Watts/ft (at operating voltage) by the operating voltage. Multiply the result times the total installed cable length in feet. Multiply this result times 1.2 to get the minimum circuit breaker size.

部品番号ビルダー

下記から仕様構成を選択し、ご注文ください
以下からオプションを選択:


(1) Watts/Foot :
4 : 4 Watts/Foot
8 : 8 Watts/Foot
12 : 12 Watts/Foot

(2) Volt :
1 : 120 Volt
2 : 240 Volt
4 : 480 Volt

(3) Type :
C : Tinned Copper Braid
CT : FEP Overcoat and Tinned Copper Overbraid
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。
ご不明な場合は、カスタマーサービス(0120-040-572 もしくは jpesales@dwyeromega.com)へお問合せください。