フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

3 1/2 Digit Mini-size Process Meter - Discontinued

DPF50

Process Meter, Low Cost - Omega | DPF50

Process Meter, Low Cost - Omega

スクロールダウンし、全ラインアップをご覧ください

5 year warranty
  • Easy to Use and No Programming Required
  • Zero and Span Adjustments of 2,000 Counts Each
  • ±1,999 Count Display Span
  • 120 dB CMR, 56 dB NMR
  • Bright, 14.2 mm (0.56") LED Display
  • EMI/RFI Filter for ac Power
  • Removable Screw-Clamp Connector
  • Miniature DIN Case with 24 x 72 mm (0.94 x 2.83") Bezel Options
  • Isolated Transmitter Excitation Supply
  • 4-20 mA, 1-5 V, 0-10 V Signal Ranges
  • Red or Green LED Display
  • 24 Vac Power Supply
  • 25 x 75 mm (0.98 x 2.96") Bezel Adaptor
  • NEMA-4 Splash-Proof Lens Cover

商品説明

DPF50 Series are discontinued. As a possible substitute, please check out the DP20 Meter for details.

Large Display, Small Case
The DPF50 Series provides a full-size 14.2 mm (0.56"), red or green LED display, yet is housed in a miniature case with a 24 x 72 mm (0.94 x 2.83") bezel. The case fits into a standard 3 //64 DIN cutout, 22.2 x 68 mm (0.87 x 2.68") and requires a depth of less than 120 mm (4.72") behind the panel, including plug-in screw-clamp connectors (standard).
Built-In Isolated Excitation
Model DPF52 is a low-cost 3 1 /2 digit (±1,999-count) process meter with a built-in, isolated excitation supply to power two- or four-wire transmitters, bridges or active transducers. Output levels of 24 Vdc at 20 mA or 10 Vdc at 30 mA are jumper-selectable.
Easy To Scale
The DPF50 Series can be shipped fully calibrated to meet a customer’s specific requirements (DPF50-FSE). Five signal ranges can be selected via push-on jumpers, and precision potentiometers are readily accessible behind the lens to provide zero and span adjustments of 2000 counts each. Accuracy is 99.9% of reading.
Multiple Power Options
The DPF50 Series incorporates a power supply, which is available for 24, 100, 115 or 230 Vac OR 7-32 Vdc power. All power options provide EMI filtering, so that power line noise does not affect the reading.

For full product specifications view pdf file in "Related Links" below

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
注: Scalable meters are factory set for a full scale display range of 000.0 to 100.0 unless customer specified at time of order.

製品マニュアル:

ダウンロード DPF50 - 3 1/2 DIGIT MINI-SIZE PROCESS METER (DPF56) WITH ISOLATED EXCITATION (DPF57)
ダウンロード DPF50 - 3/64 DIN Process Meter Quick Start
We noticed you are from the US. Visit your local site for regional offers and live support.