フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Digital Pressure Gauges with Alarms and Analog Output Functions

DPG1000 Series

Digital Pressure Gauges with Alarms and Analog Output Functions | DPG1000 Series

¥126,875 DPG1000ADA-15G-1N

  • AC or DC Powered with Dual Alarms
  • DC Powered with Dual Alarms and Analog Output
  • Ranges between 15 psi and 3000 psi
  • Normal or Reverse Acting Alarms
  • Hi/Lo, Hi/Hi, or Lo/Lo Alarms available
  • Colored LED Alarm Status Indicators
圧力計 (圧力ゲージ) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

Using the DPG1000ADA and DPG1000DAR Alarm Outputs Normal (Fail-safe) vs. Reverse Action—The convention for alarm action is that with the normal or fail-safe configuration, the alarm output relays will be CLOSED (relay energized) for a clear or non-alarm condition and OPEN (relay not energized) for an alarm condition. This is primarily for users who require an alarm condition if the gauge loses power or suffers a catastrophic failure. In the wiring diagrams, the normally closed and normally open designations refer to standard relay terminology (i.e., the relay contact status with the relay coil not energized). Therefore, with the normal (fail-safe) configuration in a green or non-alarm condition, the relay will be energized so that continuity can be expected between the common and normally open leads. In a red or alarm condition, the relay will be open (not energized) so that continuity can be expected between the common and normally closed leads.
Contact Rating and Protection The contacts of the alarm relays are rated at 1 A/24 Vdc or 0.5 A/ 115 Vac. Switching loads greater than the rating, or switching large inductive loads, will shorten the useful life of the contacts. In lowlevel switching or with dry contacts, the user should consider whether external contact protection, such as snubber networks or arc suppression networks, is required to protect the contacts. In addition, no internal fusing is included in the DPG1000 contact circuits. The circuit external to the gauge alarm outputs should be fused by the user in applications in which good design dictates this practice.
Using the DPG1000DAR Analog Output The analog output is easy to use if a few system considerations are observed. The DPG1000DAR is DC powered, with the gauge power supply (–) tied to the 4 to 20 mA (–). Therefore, the DC supply (–) lead should be considered common with regard to the analog output (–) or ground connection in the user’s system. Be sure to observe the output compliance (voltage drive) capabilities of the gauge. The compliance, and therefore the maximum loop resistance the output can drive, is a function of the supply voltage to the gauge. Consult the manual for maximum loop resistance vs. supply voltage. Too large a loop resistance will cause the gauge output to “limit” or saturate before reaching its full 20 mA output.

DPG1000ADA AC/DC Powered with Dual Alarms
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard, others available; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bicolor (red/green) LEDs on front panel
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation
Alarm Response Time: 100 ms typical
Power: Any AC source of 8 to 24 Vac, 50/60 Hz, or any DC source of 9 to 32 Vdc, 1.0 W maximum; optional wall-mount power supply available to operate on 115 Vac (DPG1000-PS)
DPG1000DAR DC Powered with Dual Alarms and 4 to 20 mA Output
SPECIFICATIONS
Accuracy: ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability)
Controls and Location: Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; test calibration level, 0 to 100% range; top-accessible, multiturn potentiometers analog output zero/span; internal potentiometers
Alarm Deadbands (Hysteresis): 1% of FSO, standard
Alarm Outputs: Dual form “C” (SPDT) relay contacts; individual setpoint 1 and setpoint 2 settings via top-accessible multiturn potentiometers; high/low alarm configuration standard; relay contacts rated 1 A/24 Vdc, 0.5 A/115 Vac, non-inductive
Alarm Indicators: Bi-color (red/green) LEDs on front panel
Alarm Response Time: 100 ms typical
Analog Output: 4 to 20 mA DC; output drive (compliance) determined by power source
Analog Output Response Time: 50 ms, typical
Test Function: Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status and simultaneously sets display and analog output to “calibration” level, independent of pressure input, to allow testing system operation
Power: Any DC source of 9 to 32 Vdc, 1.0 W max
Electrical Connection: 0.9 m (3') long, 4-conductor 22 AWG shielded cable for power and retransmitted output; 0.9 m (3') long, 6-conductor 22 AWG cable for alarm contacts

ALARMS (final siffix 1N standard)
1 = HI/LO (standard)
2= HI/HI
3= LO/LO
N = Normal Acting (standard)
R = Reverse Acting
Example: DPG1000ANA-15G-3R HAS LO/LO ALARMS, Reverse Acting

For alternative Digital Pressure Gauges please visit the following links:
DPG-108
DPG104-DPG104S
DPG-110
DPG-101
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
ABSOLUTE PRESSURE MODELS
  
DPG1000ADA-15A-1N
¥138,204 (税込)
(税抜価格 ¥125,640)
納期: 8 週間
 
Range 0 to 15.00 psi Absolute, Hi/Lo Alarms
  
DPG1000ADA-30A-1N
¥146,619 (税込)
(税抜価格 ¥133,290)
納期: 8 週間
 
Range 0 to 30 psi Absolute, Hi/Lo Alarms
GAGE PRESSURE MODELS
Click to expand/minimize a list of what others bought with theDPG1000ADA-15G-1N
DPG1000ADA-15G-1N
¥139,563 (税込)
(税抜価格 ¥126,875)
納期: 8 週間
 
Range (psi) 0 to 15.00, Hi/Lo Alarms
  
DPG1000ADA-30G-1N
¥138,204 (税込)
(税抜価格 ¥125,640)
納期: 8 週間
 
Range (psi) 0 to 30, Hi/Lo Alarms
Click to expand/minimize a list of what others bought with theDPG1000ADA-100G-1N
DPG1000ADA-100G-1N
¥138,969 (税込)
(税抜価格 ¥126,335)
納期: 2 週間
 
Range (psi) 0 to 100, Hi/Lo Alarms
  
DPG1000ADA-200G-1N
¥138,204 (税込)
(税抜価格 ¥125,640)
納期: 8 週間
 
Range (psi) 0 to 200, Hi/Lo Alarms
Click to expand/minimize a list of what others bought with theDPG1000ADA-300G-1N
DPG1000ADA-300G-1N
¥138,969 (税込)
(税抜価格 ¥126,335)
納期: 7 週間
 
Range (psi) 0 to 300, Hi/Lo Alarms
  
DPG1000ADA-500G-1N
¥138,969 (税込)
(税抜価格 ¥126,335)
納期: 8 週間
 
Range (psi) 0 to 500, Hi/Lo Alarms
  
DPG1000ADA-1KG-1N
¥138,204 (税込)
(税抜価格 ¥125,640)
納期: 8 週間
 
Range (psi) 0 to 1000, Hi/Lo Alarms
  
DPG1000ADA-3KG-1N
¥144,689 (税込)
(税抜価格 ¥131,535)
納期: 8 週間
 
Range (psi) 0 to 3000, Hi/Lo Alarms
ACCESSORY
Click to expand/minimize a list of what others bought with theDPG1000-PS
DPG1000-PS
¥7,920 (税込)
(税抜価格 ¥7,200)
納期: 2 週間
 
Wall Mount 115Vac Power Supply
注: Comes complete with operator’s manual. Note: To order another alarm configuration, replace “-1N” with alarm configuration from table above.
Ordering Example: (1) DPG1000ADA-15G-1N AC/DC powered, 15 psig range, two alarms, one Hi, one Lo, ¥126,875