フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Multi-Parameter Input Transmitter For Conductivity, Resistivity and Salinity

DPU91_Conductivity

Multi-Parameter Input Transmitter For Conductivity, Resistivity and Salinity | DPU91_Conductivity

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE
  • Large Auto-Sensing Backlit Display
  • “Dial-Style” Digital Bar Graph
  • Intuitive and “User-Friendly” Interface
  • Optional Field Upgradable Relays
  • Warning LED Indicator
  • Custom 13-Character Label Capabilities
  • Factory Reset Capability
導電率計 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The DPU91 transmitter provides a single channel interface for many different parameters including flow, pH/ORP, conductivity/resistivity, salinity and temperature. The DPU91-BC transmitter has the added capability of supporting the batch module for batching control. The extra-large (3.90 x 3.90") autosensing backlit display can be viewed at 4 to 5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a “dial-style” digital bar graph. The DPU91 is offered in both panel or field-mount versions. Both configurations can run on 12 to 32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs. Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include relay, direct conductivity/ resistivity, batch and a PC communications configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.

Specifications
General
Input Channels: 1
Input Types: Digital serial ASCII, TTL level, 9600 bps
Frequency Range: 0.5 to 1500 Hz
Accuracy: 0.5% of reading (display)
Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch
Enclosure and Display
Case Material: PBT
Window: Shatter-resistant glass
Keypad: 4 buttons, injection-molded silicone rubber seal
Display: Backlit, 7 and 14-segment
Update Rate: 1 second
LCD Contrast: 5 settings
Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
Enclosure: ¼ DIN, NEMA 4X/IP65
Mounting Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)
Field Mounts: Specified to OMEGA™ field mount junction boxes
Weight: 0.63 kg (1.38 lb)
Display Ranges
For PH/ORP version visit omega.com/dpu91_ph For flow version visit omega.com/ dpu91_flow
Conductivity: 0.0000 to 99999 µS, mS, PPM and PPB (TDS), kΩ, MΩ
Conductivity Temperature: -99 to 350°C (-146 to 662°F)
Temperature: -99 to 350°C (-146 to 662°F)
Salinity: 0 to 100 PPT
Environmental
Ambient Operating Temperature:
    Backlit LCD: -10 to 70°C (14 to 158°F)
    Storage Temperature: -15 to 70°C (5 to 158°F)
Relative Humidity: 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
Maximum Altitude: 4000 m (13,123')
Electrical Requirements
Power to Sensors:
    Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
    Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge
Input Power
DC: 10.8 to 35.2 Vdc, regulated
Current Output:
4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)
Open Collector:1
Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
Relay Specifications (DPU91-R)
Dry-Contact Relay:
Type: SPDT, Form C
Maximum Current Rating: 5 A resistive 50 mA DC
Maximum Voltage Rating: 30 Vdc or 250 Vac
Hysteresis Adjustable: Absolute in engineering units (EUs)
Latch Reset: In test screen only
Delay: 9999.9 seconds (maximum)
Test Mode: Set on/off
Cycle Time: 99999 seconds (maximum)
Maximum Pulse Rate: 400 pulses/minute
Proportional Pulse: 400 pulses/minute
Volumetric Pulse Width: 0.1 to 3200 s
Pulse Width Modulation: 0.1 to 320 s
Input Types
Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics for pH/ORP models visit omega.com/ dpu91_ph. For flow models visit omega.com/dpu91_flow
Raw Conductivity/Resistivity: Input directly from signet conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850
Input Specifications
Digital Serial: ACSII, TTL level, 9600 bps
Frequency Input:
    Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency
    Span: 0.5 Hz to 1500 Hz @ TTL level input
Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F)
Resolution: 1 µS
Repeatability: ±0.2% of reading
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
Click to expand/minimize a list of what others bought with theDPU91
DPU91
¥124,817 (税込)
(税抜価格 ¥113,470)
納期: 2 週間
 
DC powered field mount multi-parameter display and transmitter (Requires FP90UM universal mounting kit)
Click to expand/minimize a list of what others bought with theDPU91P
DPU91P
¥116,947 (税込)
(税抜価格 ¥106,315)
納期: 2 週間
 
DC powered panel mount multi-parameter display and transmitter
Required Module for Conductivity
Click to expand/minimize a list of what others bought with theDPU90-C
DPU90-C
¥56,689 (税込)
(税抜価格 ¥51,535)
納期: 2 週間
 
Conductivity/Resistivity/Salinity direct input module (required for Conducitivty measurement)
Conductivity Sensors
Click to expand/minimize a list of what others bought with theCDCE-90-001
CDCE-90-001
¥90,461 (税込)
(税抜価格 ¥82,237)
納期: 2 週間
 
Conductivity sensor, 3⁄4 NPT, cell constant 0.01, 316 SS
Click to expand/minimize a list of what others bought with theCDCE-90-01
CDCE-90-01
¥95,761 (税込)
(税抜価格 ¥87,055)
納期: 4 週間
 
Conductivity sensor, 3⁄4 NPT, cell constant 0.01, 316 SS
Click to expand/minimize a list of what others bought with theCDCE-90-1
CDCE-90-1
¥95,761 (税込)
(税抜価格 ¥87,055)
納期: 9 週間
 
Conductivity sensor, 3⁄4 NPT, cell constant 1, 316 SS
Click to expand/minimize a list of what others bought with theCDCE-90-10
CDCE-90-10
¥159,148 (税込)
(税抜価格 ¥144,680)
納期: 16 週間
 
Conductivity sensor, 3⁄4 NPT, cell constant 10, 316 SS
  
CDCE-90-20B
¥195,564 (税込)
(税抜価格 ¥177,785)
納期: 16 週間
 
Conductivity sensor, 3⁄4 NPT, cell constant 20, 316 SS, PEEK
  
CDCE-90S-001-S15
¥210,403 (税込)
(税抜価格 ¥191,275)
納期: 16 週間
 
Conductivity sensor, 1⁄2" sanitary, cell constant 0.01, 316 SS
  
CDCE-90S-001-T15
お問い合せ下さい   
納期: 
 
 
Conductivity sensor, 1" sanitary, cell constant 0.01, Titanium
  
CDCE-90S-01-S20
お問い合せ下さい   
納期: 
 
 
Conductivity sensor, 2" sanitary, cell constant 0.1, 316 SS
  
CDCE-90S-1-S15
¥191,521 (税込)
(税抜価格 ¥174,110)
納期: 10 週間
 
Conductivity sensor, 11⁄2" sanitary, cell constant 1, 316 SS
  
CDCE-90S-1-S20
¥225,198 (税込)
(税抜価格 ¥204,725)
納期: 10 週間
 
Conductivity sensor, 2" sanitary, cell constant 1, 316 SS
Accessories
  
DPU90-AK
¥6,732 (税込)
(税抜価格 ¥6,120)
納期: 8 週間
 
Angle adjustment kit for field mount
  
DPU90-COMM
¥70,213 (税込)
(税抜価格 ¥63,830)
納期: 8 週間
 
Communications module, HART® (Panel mount only!)
  
DPU90-CT
¥62,150 (税込)
(税抜価格 ¥56,500)
納期: 14 週間
 
PC configuration tool, includes software
  
DPU90-R
¥26,527 (税込)
(税抜価格 ¥24,115)
納期: 2 週間
 
Programmable dual relay output module (Panel mount only!)
Mounting Options
Click to expand/minimize a list of what others bought with theFP90UM
FP90UM
¥17,045 (税込)
(税抜価格 ¥15,495)
納期: 2 週間
 
Universal mounting bracket for field mounted units
Conductivity Solutions
Click to expand/minimize a list of what others bought with theCDSA-10
CDSA-10
¥15,586 (税込)
(税抜価格 ¥14,169)
納期: 3 週間
 
*10 µ/cm conductivity solution
  
CDSA-15
お問い合せ下さい   
納期: 
 
 
*15 µ/cm conductivity solution
Click to expand/minimize a list of what others bought with theCDSA-45
CDSA-45
¥3,830 (税込)
(税抜価格 ¥3,482)
納期: 3 週間
 
45 µ/cm conductivity solution
Click to expand/minimize a list of what others bought with theCDSA-450
CDSA-450
¥3,830 (税込)
(税抜価格 ¥3,482)
納期: 3 週間
 
450 µ/cm conductivity solution
Click to expand/minimize a list of what others bought with theCDSA-1413
CDSA-1413
¥8,950 (税込)
(税抜価格 ¥8,136)
納期: 2 週間
 
1413 µ/cm conducitivity solution
Click to expand/minimize a list of what others bought with theCDSA-1500
CDSA-1500
¥3,830 (税込)
(税抜価格 ¥3,482)
納期: 3 週間
 
1500 µ/cm conducitivity solution
Click to expand/minimize a list of what others bought with theCDSA-4500
CDSA-4500
¥4,047 (税込)
(税抜価格 ¥3,679)
納期: 3 週間
 
4500 µ/cm conductivity solution
Click to expand/minimize a list of what others bought with theCDSA-45000
CDSA-45000
¥3,938 (税込)
(税抜価格 ¥3,580)
納期: 4 週間
 
4500 µ/cm conductivity solution
注: Comes complete with operator’s manual.

Sensors and mounting kits sold separately.

The DPU90-C is required for use with conductivity measurement. The DPU90-C is sold separately.

* 6-month shelf life


製品マニュアル:

ダウンロード Transmitter
ダウンロード PC COMM Sensor Configuration Tool
We noticed you are from the US. Visit your local site for regional offers and live support.