フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

DIN Rail 2-Wire Transmitter Isolators

DRSL-LPO_Series

DIN Rails - 2-Wire Transmitter Isolators | DRSL-LPO_Series

DIN Rails - 2-Wire Transmitter Isolators

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE
  • 1 Channel (DRSL-LPO-1) or 2 Channel (DRSL-LPO-2) 2-Wire Transmitter Isolators
  • Powered By the Host (Output) Current Signal Loop
  • 1:1 Signal Ratio
  • Low Channel Voltage Drop
  • Available Input Transmitter (Tx) Supply
  • Fast Response Time <5 ms
  • High Conversion Accuracy, <0.05% of Span (3.8 to 20.5 mA)
  • Slimline 6 mm (0.24") Housing
プロセス計測 / 制御機器 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The DRSL-LPO Series DIN rail 2-wire transmitter isolators provide a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. These units provide isolation and 1:1 conversion of standard current signals and are powered by the host (output) current signal loop. Input transmitter (Tx) power supply of 3.5 to 32.5V is provided.

The DRSL-LPO series offers isolation between input and output, provides surge suppression and protects control systems from transients and noise. These units also eliminate ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. These isolators operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

SPECIFICATIONS
NUMBER OF CHANNELS
    DRSL-LPO-1: 1
    DRSL-LPO-2: 2
CURRENT INPUT
    Signal Range (Input to Output): 3.8 to 20.5 mA
    Signal Conversion: 1:1
    Functional Range: 3.5 to 23 mA (NAMUR NE43 compliant)
Available 2-Wire Transmitter (Tx) Supply: 3.5 to 32.5V
CURRENT OUTPUT
Output Loop Current Limitation: 24 mA typical
Output Overload: 50 mA max

GENERAL
Supply Voltage: 6 to 35 Vdc
Internal Consumption: 50 mW per channel
Voltage Drop (Input to Output): 2.5V typical
Isolation Voltage (Test): 2.5 kVac
Isolation Voltage (Working): 300 Vac
Signal/Noise Ratio: >60 dB
Cut-Off Frequency (3 dB): 100 Hz
Response Time (0 to 90%, 100 to 10%): <5 ms
Absolute Accuracy (at 25°C): ≤±8 µA
Temperature Coefficient (>25°C): ≤±0.02 µA [(T-25°C) x Vsupply]
Temperature Coefficient (<25°C): ≤±0.07 µA [(T-25°C) x Vsupply]
EMC Immunity Influence: <±0.5% of span (4 to 20 mA)
Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span

ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II

MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm²/ AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
DRSL-LPO-1
¥34,634 (税込)
(税抜価格 ¥31,485)
納期: 6 週間
 
DIN rail 2-wire transmitter isolator, 1 channel
DRSL-LPO-2
¥50,452 (税込)
(税抜価格 ¥45,865)
納期: 2 週間
 
DIN rail 2-wire transmitter isolator, 2 channel
Accessories
RAIL-35-1
¥3,274 (税込)
(税抜価格 ¥2,976)
納期: 2 週間
 
35 mm (1.4") DIN rail, 1 m (3.3') length
DRSL-MOD-STOP
¥1,617 (税込)
(税抜価格 ¥1,470)
納期: 5 週間
 
Module stop (screwed onto DIN rail to support and hold mounted devices)
Ordering Example: (1) DRSL-LPO-1 DIN rail 2-wire transmitter isolator, 1 channel, ¥31,485  plus (1) DRSL-MOD-STOP Module stop (screwed onto DIN rail to support and hold mounted devices), ¥1,470  plus (1) RAIL-35-1 35 mm (1.4, ¥2,976, ¥31,485 + 1,470 + 2,976 = ¥35,931

製品マニュアル:

ダウンロード Installation Guide for Signal Conditioners
ダウンロード DIN Rail Loop Powered Isolators
We noticed you are from the US. Visit your local site for regional offers and live support.