FMA-LP2600A
MASS FLOW CONTROLLER | GAS FLOW
¥1,004,020
FMA-LP2612A
-
130+ Gas Calibrations Including Pure and Mixed Gases
-
Pressure, Temperature, and Mass Flow Simultaneously Displayed
-
Easy-to-Use Pushbutton Interface
-
NIST Traceability Standard
-
Full Scale Ranges from 0.5 SCCM to 500 SLM
-
Response Time of 50 to 100 ms Typical
-
Turndown Ratio of 200:1
-
Position Insensitive
-
±0.8% Reading Accuracy
-
RS232 Standard
-
Custom Live Gas Blend Programming
-
Store Up to 20 User Defined Gas Blends
質量流量計 (マスフローメータ) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)
注: Comes complete with 24 Vdc universal power supply, 1.8 m (6') cable, 8-pin male Mini- DIN connector, operator's manual, and NIST certificate.
Standard units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.
For custom calibrations, add "-(*)" to the model number, no additional cost. *Specify gas, and inlet/outlet or backpressure for custom calibrations.
Calibrations done at ambient (25°C/77°F) temperature only.
To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.
Standard input is 0-5V, for optional 4-20 mA input add suffix "-IN" to the model number, no additional cost.
Optional secondary output are scaled the same as the primary output scale. For an alternate output scale add suffix "-T" to the model number for temperature or "-P" for pressure, no additional cost.
For units scaled in SCFH, add suffix "-SCFH" to model number, no additional cost. Please specify the desired range in SCFH.
For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution.
This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.
For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').
Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.
部品番号ビルダー
以下からオプションを選択:
(1)
Max Flow :01 : 0.5 SCCM
02 : 1 SCCM
14 : 2 SCCM
15 : 5 SCCM
03 : 10 SCCM
16 : 20 SCCM
04 : 50 SCCM
17 : 100 SCCM
18 : 200 SCCM
19 : 500 SCCM
20 : 1 SLM
05 : 2 SLM
06 : 5 SLM
07 : 10 SLM
08 : 20 SLM
09 : 50 SLM
10 : 100 SLM
11 : 250 SLM
12 : 500 SLM
(2)
Output :オプション選択がない場合 : None
-I : 4 to 20 mA output
-I2 : Two 4 to 20 mA outputs
-V2 : Two 0 to 5V Outputs
-I2-T : Two 4 to 20 mA outputs second output for temperature
-V2-T : Two 0 to 5V outputs second output for temperature
-I2-P : Two 4 to 20 mA outputs second output for pressure
-V2-P : Two 0 to 5V outputs second output for pressure
-VOL : Volumetric flow rate as standard output
(3)
Portable Version :オプション選択がない場合 : Standard
-B : Portable version of the meter (not available on models with 4 to 20 mA output)
(4)
Input :オプション選択がない場合 : 0 to 5V
-IN : 4 to 20 mA input
(5)
RS485 :オプション選択がない場合 : RS232
-RS485 : RS485
(6)
SCFH :オプション選択がない場合 : Standard
-SCFH : Units scaled in SCFH
(7)
Totalizer :オプション選択がない場合 : Standard
-TOT : Totalizer
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。