注: Comes complete with 24 Vdc power supply, 1.8 m (6') cable, 8 pin male mini DIN connector, operator’s manual and NIST certificate.
††Portable versions "-B" have an integral battery compartment and come complete with 24 Vdc power supply, 1.8m (6') cable, 8 pin male mini DIN connector, operator's manual, NIST certificate, and 9V battery installed. Portable version is not available on models with 4 to 20 mA output.
Units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.
Calibrations done at ambient (25°C/77°F) temperature only.
To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.
Standard output is scaled to the mass flow rate. For volumetric flow rate as standard output add "-VOL" to the model number.
Optional secondary output are scaled the same as the primary output. For a different secondary output scale add suffix "-T" for temperature or suffix "-P" for pressure, no additional cost.
Add "-SCFH" to model number for units scaled in SCFH, no additional charge. Specify required range in SCFH.
For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution. This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.
High accuracy calibrations to ±0.5% of full scale are available on models having a minimum full scale range of 10 SCCM or greater. For a high accuracy calibration add suffix "-HACAL" to the model number, add $400 to the price.
For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.
Ordering Example: (1) FMA1613A Mass Flowmeter, 3/4, ¥565,445
部品番号ビルダー
以下からオプションを選択:
(1)
Max Flow :01 : 0.5 SCCM
02 : 1 SCCM
14 : 2 SCCM
15 : 5 SCCM
03 : 10 SCCM
16 : 20 SCCM
04 : 50 SCCM
17 : 100 SCCM
18 : 200 SCCM
19 : 500 SCCM
20 : 1 SLM
05 : 2 SLM
06 : 5 SLM
07 : 10 SLM
08 : 20 SLM
09 : 50 SLM
10 : 100 SLM
11 : 250 SLM
12 : 500 SLM
13 : 1000 SLM
21 : 1500 SLM
22 : 2000 SLM
23 : 3000 SLM
(2)
Output :オプション選択がない場合 : None
-I : 4 to 20 mA output
-I2 : Two 4 to 20 mA outputs
-V2 : Two 0 to 5V Outputs
-I2-T : Two 4 to 20 mA outputs second output for temperature
-V2-T : Two 0 to 5V outputs second output for temperature
-I2-P : Two 4 to 20 mA outputs second output for pressure
-V2-P : Two 0 to 5V outputs second output for pressure
-VOL : Volumetric flow rate as standard output
(3)
Portable Version :オプション選択がない場合 : Standard
-B : Portable version of the meter (not available on models with 4 to 20 mA output)
(4)
Input :オプション選択がない場合 : 0 to 5V
-IN : 4 to 20 mA input
(5)
RS485 :オプション選択がない場合 : RS232
-RS485 : RS485
(6)
SCFH :オプション選択がない場合 : Standard
-SCFH : Units scaled in SCFH
(7)
Totalizer :オプション選択がない場合 : Standard
-TOT : Totalizer
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。