FMA-2600 SERIES
Mass Flow Controllers with 20+ Gas Select Function
スクロールダウンし、全ラインアップをご覧ください
-
130+ Gas Calibrations, Including: He, O2 , Neon, N2O, N2, Air, Argon, CO, CO2, Methane, Ethane, Propane, Butane, Acetylene, Ethylene, H2
-
Pressure, Temperature, Volumetric & Mass Flow Simultaneously Displayed
-
Easy Operator Push Button Interface
-
NIST Traceability Standard
-
Full Scale Ranges from 0.5 SCCM to 3000 LPM
-
Response Time of 100 milliseconds Typical
-
Turndown Ratio of 100:1 Typical
-
Position Insensitive
-
Accuracy of ±1% Full Scale
-
RS232 Standard
-
No Warm Up Time
質量流量計 (マスフローメータ) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)
注: Comes complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini- DIN connector, operator's manual, and NIST certificate.
Standard units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.
For custom calibrations, add "-(*)" to the model number, no additional cost. *Specify gas, and inlet/outlet or backpressure for custom calibrations.
Calibrations done at ambient (25C/77F) temperature only.
To replace the standard RS232 communications with RS485, add suffix "-RS485" to the model number, add $120 to the price.
Standard input is 0-5V, for optional 4-20 mA input add suffix "-IN" to the model number, no additional cost.
Standard output is scaled to the mass flow rate. For volumetric flow rate as standard output add suffix "-VOL" to the model number. For "-VOL" controllers the control loop is set to volumetric as standard.
Optional secondary output are scaled the same as the primary output scale. For an alternate output scale add suffix "-V2T" for voltage scaled for temperature, "-I2T" for current scaled for temperature, "-V2P" for voltage scaled for pressure or "-I2P" for current scaled for pressure, no additional cost.
For units scaled in SCFH, add suffix "-SCFH" to model number, no additional cost. Please specify the desired range in SCFH.
For totalizer option, add suffix "-TOT" to the model number, add $120 to the price. Please specify resolution.
This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.
For a Remote Display, add suffix "-RD-*FT" to the model number, add $210 to the price. Replace the * in the suffix with the required length in whole feet, the maximum length is 3.6576 m (12'). Please note the optimum distance in feet is between 2.7 to 3 m (9 to 10').
Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.
Ordering Example: (1) FMA-2601A-I2 10-32 Thread Mass Gas Flow Controller with optional second channel output of 4-20mA, ¥580,160
部品番号ビルダー
以下からオプションを選択:
(1)
Flow Range :01 : 0.5 SCCM
02 : 1 SCCM
14 : 2 SCCM
15 : 5 SCCM
03 : 10 SCCM
16 : 20 SCCM
04 : 50 SCCM
17 : 100 SCCM
18 : 200 SCCM
19 : 500 SCCM
20 : 1 SLM
05 : 2 SLM
06 : 5 SLM
07 : 10 SLM
08 : 20 SLM
09 : 50 SLM
10 : 100 SLM
11 : 250 SLM
12 : 500 SLM
13 : 1000 SLM
21 : 1500 SLM
22 : 2000 SLM
23 : 3000 SLM
(2)
Output :オプション選択がない場合 : None
-I : 4 to 20 mA output
-I2 : Two 4 to 20 mA outputs
-V2 : Two 0 to 5V Outputs
-I2T : Two 4 to 20 mA outputs second output for temperature
-V2T : Two 0 to 5V outputs second output for temperature
-I2P : Two 4 to 20 mA outputs second output for pressure
-V2P : Two 0 to 5V outputs second output for pressure
-VOL : Volumetric flow rate as standard output
(3)
Integrated positive shut-off valve :オプション選択がない場合 : Standard
-P : Integrated positive shut-off valve (only available on models up to 20 SLM)
(4)
Input :オプション選択がない場合 : 0 to 5V
-IN : 4 to 20 mA input
(5)
RS485 :オプション選択がない場合 : RS232
-RS485 : RS485
(6)
SCFH :オプション選択がない場合 : Standard
-SCFH : Units scaled in SCFH
(7)
Totalizer :オプション選択がない場合 : Standard
-TOT : Totalizer
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。
ご不明な場合は、カスタマーサービス(0120-040-572 もしくは jpesales@dwyeromega.com)へお問合せください。