High Outlet Pressure Capability of 100 psig on Most Models
Acceptable for Indoor Use
Corrosion Proof Valox Housing
Tamper Resistant Electronic Control Panel Cover
Tube Failure Detection
商品説明
The FPU2000 series has been discontinued. Please see the FPU2000A Series as a possible alternative or contact our Flow Engineering department.
The FPU2000 Series fixed pumps
feed by an analog fixed 60 second
timer. The pump can be on for 1 to
60 seconds. All FPU2000 Series
have fixed speed outputs and can
be adjusted by selecting the pumphead tube size and choosing
the desired RPM (revolutions per
minute).
The FPUVS2000 and
FPUDVS2000 Series variable
speed pumps are for continuous
pumping relatively pulse free, even while
adjusting the percentage of output.
The variable speed pump requires
the use of brushes on the DC
motor. Excellent brush life
expectancy (2000 hours). An extra
set of brushes included with every
pump.
The FPUDVS2000 Series
will accept any one of three
different types of external input
signals; 4 to 20 mA, 0 to 10 Vdc,
or frequency. The 4 to 20 mA and
0 to 10 Vdc loops must be powered.
Two types of frequency inputs, AC
sine waves (magnetic coils type
outputs) and digital square waves
(Hall Effect signals, contact
closures), are acceptable. A jumper
plug located on the circuit board is
factory pre-set for AC sine wave
signals, the jumper must be
re-positioned when digital square wave signals are being used. All
wiring connections are to be made
inside of the junction box located
on the side of the FPUDVS2000
Series.
A liquid tight connector is
supplied and should be used for the
external signal cable. The signal
input wires are color coded to the
type of signal being used.
SPECIFICATIONS Maximum Working Pressure: 100 psig/6.9 bar (most models) Maximum Fluid Temperature: 54°C (130°F) Ambient Temperature Range: -10 to 43°C (14 to 110°F) Enclosure: NEMA 3R (IP24) (acceptable for indoor use) Pump Tube Material: Norprene Duty Cycle: Continuous Maximum Solids: 50% by volume Maximum Viscosity: 5000 Centipoise Maximum Suction Lift: Up to 9 m (30') water Turn Down Ratio: 20:1 Power Requirements: 115 V 60 Hz 80 Watts, 220 V 50 Hz 40 Watts, 230 V 60 Hz 45 Watts Variable Speed: 115 V 60 Hz 40 Watts, 220 V 50 Hz 40 Watts, 230 V 60 Hz 40 Watts Dimensions: 155.6 H x 257.2 W x 228.6 mm D (61⁄8 x 101⁄8 x 9") Variable Speed: 159 H x 254 W x 235 mm D (6¼ x 10 x 9¼") Weight: 3.6 kg (8 lb) Tube Connection: Compression barb type (3⁄8" ID x ¼" OD)
注: Comes complete with suction tube strainer, tube weight, suction tubing, discharge tubing and injection fitting with internal back-flow check valve, mounting hardware, and operator’s manual.
FPUVS and FPUDVS come with an additional set of brushes.
For optional CE approved 220 Vac/50Hz add suffix "-220/50" to model number, no additional charge.
For optional CE approved 230 Vac/60 Hz model add suffix "-230/60" to model number, no additional charge.
Note: 220 Vac/50Hz fixed speed models output approximately 20% less.