フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

FTB3001,FTB3002

Positive Displacement (PD) Flowmeters | FTB3001,FTB3002

Positive Displacement (PD) Flowmeters

¥1,072,695 FTB3002

1 year warranty CE
  • Toothless Oval Gear Construction (Patented)
  • High Accuracy
  • Compact Design
  • High Resolution Electronic Output
  • Temperatures to 176°C (350°F)
  • Pressure Rated to 3000 PSIG with 1 NPT Fitting Standard
  • Multiple Bearing Options
  • 316 Stainless Steel Construction (Standard)
  • No Special Gears Needed for High Viscosity
  • Linearity Unaffected by Viscosity Changes
  • 1 MNPT End Fitting Standard, Flange Optional
タービン流量計 (羽根車式) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The oval-shaped smooth gears in the FTB3000 Series are used to displace a precise volume of fluid,which is passed through th emeasurement chamber during each revolution. The toothless design,working with the fluid being measured, provides a complete viscous seal within the measuring chamber. This sealing effect provides for greater flow measurement accuracy.

The displacement of the fluid is translated via a magnetic or Hall-effect pick-up into a pulse output that is proportional to the flow.

The unique design of the FTB3000 oval gear meter incorporates two smooth(toothless) oval gears positioned 90 degrees out of phase. The measurement gears are held together by two timing gears. The standard meter contains no seal between the measurement chamber and the timing chamber. The timing gears have a pitch diameter equal to the outside diameter of the measurement gears. The flow through the meter measurement chamber follows the path of least resistance. Therefore, no liquid passes through the center cavity between the measurement gears. The fluid is displaced from the inlet to the outlet via the area between the smooth oval gear and the inner diameter of the meter housing.

Conventional oval gears have teeth that mesh. One of the advantages of smooth oval gears is that the viscous flow does not get trapped or squeezed between the gears. Typically, oval gears need to have cuts made in the teeth to allow high viscosity fluids to pass. These cuts result in a decrease in accuracy.

SPECIFICATIONS
Service Fluid: Clean liquids, max particle size 3.175 mm (0.125")
Accuracy: ±0.25% of reading
Viscosity: 100 cSt or greater
Repeatability: ±0.05%
Operating Temperature:
FTB3001: -240 to 176°C (-400 to 350°F)
FTB3002: -40 to 150°C (-40 to 302°F)
Operating Pressure: 3000 psig standard
Wetted Parts: 316 SS body and gears with PEEK™ gear seats
Bearings: Shielded, self-lubricating 440 SS ball bearings
Connections: 1 MNPT
Pick Up Coil: Magnetic type or Hall Effect (6 to 24 Vdc power)
Calibration: Ten-point calibration traceable to NIST @ 100 centistokes
Weight: 7.53 kg (16.6 lb)
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
  
FTB3001
¥1,223,519 (税込)
(税抜価格 ¥1,112,290)
納期: 10 週間
 
2 to 25 GPM rate, magnetic pick-up
  
FTB3002
¥1,179,965 (税込)
(税抜価格 ¥1,072,695)
納期: 10 週間
 
0.02 to 25 GPM rate, Hall-effect sensor
Accessories
Click to expand/minimize a list of what others bought with theU24Y175
U24Y175
お問い合せ下さい   
納期: 
 
 
24 Vdc, 175 mA power supply
Click to expand/minimize a list of what others bought with theDPF701
DPF701
お問い合せ下さい   
納期: 
 
 
Panel meter for rate or total
  
MS3106F-10SL-3S
¥22,952 (税込)
(税抜価格 ¥20,865)
納期: 2 週間
 
Replacement mating connector for FTB3000 Series
注: Add suffix “-150LBF” (150 lb stainless steel flange) or “-300LBF” (300 lb stainless steel flange) to the part number and $250 to the price.

Comes complete with operator’s manual, mating connector, and 10-point NIST calibration.


Ordering Example: (1) FTB3002 Hall effect output, max temp. 150°C (302°F) unit with operator’s manual and 10-point NIST calibration, ¥1,072,695
We noticed you are from the US. Visit your local site for regional offers and live support.