¥49,830 FTB8007HW

1 year warranty
  • Flow Rates from 0.22 to 132 GPM
  • 150 psi Maximum Operating Pressure
  • 90°C (194°F) Maximum Operating Temperature
  • Field-Adjustable Pulse Output (Optional)
タービン流量計 (羽根車式) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The FTB8000HW Series meters use the multi-jet principle, which has been an internationally accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in lowquality water. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the dials is replaced by a gear, which turns a magnet that is detected by an encapsulated sensor threaded into the outside of the lens. Pulse rate is determined by the gear and the dial on which the gear is placed. Changing the pulse rate requires no special tools and can be done in the field.

Mechanically, all FTB8000HW meters are the same. The difference between the -PR, -PT, and standard models is in the sensor. -PR model meters use a solid state, longlasting Hall-effect sensor, which requires power. -PT model meters use a 2-wire reed switch. They provide a dry-contact closure and do not require power. Basic FTB8000HW meters totalize only and do not have an output. Never install water meters above or over areas where leakage would cause damage.

SPECIFICATIONS
Materials:
    Body: Cast bronze
    Internals: Engineered thermoplastic
    Magnet: Permanent ceramic
Max Temperature: 90°C (194°F)
Max Operating Pressure: 150 psi
Accuracy: 1.5% of reading
Sensor:
    -PR: Hall-effect device
    -PT: Reed switch
Max Current: 20 mA
Max Voltage:
    -PR: 24 Vdc
    -PT: 24 Vdc or Vac
Sensor Power (-PR): Minimum 6 mA at 12 Vdc
Cable Length: 4 m (12') standard, 600 m (2000') max
Flow Rates (GPM):
NPT Size ¾ 1 2
Minimum 0.22 0.44 0.88 1.98
Maximum 22 52 88 132
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
FTB8007HW
¥54,813 (税込)
(税抜価格 ¥49,830)
納期: 6 週間
 
3/4NPT, 0.22 to 22 GPM, total only
FTB8010HW
¥86,075 (税込)
(税抜価格 ¥78,250)
納期: 2 週間
 
1NPT, 0.44 to 52 GPM, total only
FTB8015HW
¥173,030 (税込)
(税抜価格 ¥157,300)
納期: 6 週間
 
1 1/2NPT, 0.88 to 88 GPM, total only
FTB8020HW
¥250,074 (税込)
(税抜価格 ¥227,340)
納期: 6 週間
 
2NPT, 1.98 to 132 GPM, total only
FTB8007HW-PT
¥58,779 (税込)
(税抜価格 ¥53,435)
納期: 2 週間
 
3/4NPT, 0.22 to 22 GPM, 20 Pulse/gallon
FTB8010HW-PT
¥94,221 (税込)
(税抜価格 ¥85,655)
納期: 2 週間
 
1NPT, 0.44 to 52 GPM, 1 Pulse/gallon
FTB8015HW-PT
¥172,585 (税込)
(税抜価格 ¥156,895)
納期: 6 週間
 
1 1/2NPT, 0.88 to 88 GPM, 1 Pulse/gallon
FTB8020HW-PT
¥259,980 (税込)
(税抜価格 ¥236,345)
納期: 6 週間
 
2NPT, 1.98 to 132 GPM, 1 Pulse/gallon
FTB8007HW-PR
¥64,939 (税込)
(税抜価格 ¥59,035)
納期: 6 週間
 
3/4NPT, 0.22 to 22 GPM, 1 Pulse/gallon
FTB8010HW-PR
¥106,546 (税込)
(税抜価格 ¥96,860)
納期: 6 週間
 
1NPT, 0.44 to 52 GPM, 1 Pulse/gallon
FTB8015HW-PR
¥200,899 (税込)
(税抜価格 ¥182,635)
納期: 6 週間
 
1 1/2NPT, 0.88 to 88 GPM, 1 Pulse/gallon
FTB8020HW-PR
¥286,396 (税込)
(税抜価格 ¥260,360)
納期: 6 週間
 
2NPT, 1.98 to 132 GPM, 1 Pulse/gallon
注: Comes with 2 MNPT couplings (already installed), 4m (12') cable, and complete operator’s manual. Only units that have an output signal (-PR or -PT) come with a cable.