フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Ball Bearing Gas Turbine Flow meters with Male NPT Fittings

FTB-930

Ball Bearing Gas Turbine Flow meters with Male NPT Fittings | FTB-930

Ball Bearing Gas Turbine Flow meters with Male NPT Fittings

スクロールダウンし、全ラインアップをご覧ください

1 year warranty
  • ±1% of Reading Accuracy
  • Ball Bearing Design for Economy
  • 440C Bearing Retainers for Durability
  • Ball Bearings Field Replaceable Without Loss of Calibration
  • Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
  • NIST Certificate Supplied Standard

商品説明

The FTB930/940 series has been discontinued. Please see the FTB1400 SERIES as a possible alternative or contact our Flow Engineering department.

The OMEGA™ FTB-930 & FTB-940 Series turbine meters have male NPT end fittings for easy connections. They are suitable for use with gases with a minimum density of 0.025 lb/ft 3 (air at STP is 0.0752 lb/ft 3 ).These units come supplied with a mating 2-wire connector and can be supplied with integrally mounted FLSC-60 Series signal conditioners to provide 4-20 mA, 0-5 V, or amplified pulse outputs. These turbine gas meters are intended for clean service only; where there is any doubt about the fluid, strainers are recommended.

OMEGA™ precision turbine gas flowmeters are designed to measure actual cubic feet or actual volume passing through the meter. Before sizing a flowmeter, it is necessary to convert flow units (i.e., SCFM, LPM, etc.) to actual units. To convert to actual measured volume (ACFM) from standard volume (SCFM), use the following formula:
ACFM = SCFM x 14.7/Pa x Ta/530
where:
ACFM = Actual cubic feet per minute of measured gas flow
SCFM = Standard cubic feet per minute gas flow
Pa = Operating pressure (psia) in = (psig + 14.7)
Ta = Temperature in degrees, Rankine = (°F + 460)


SPECIFICATIONS
Accuracy: ±1.0% of reading
Repeatability: ±0.25%
Materials of Construction:
Body: 304/316 stainless steel
Rotor: 17-4 PH SS
Bearings: 440C stainless steel
Output: 30 mV p-p sinewave min.
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
  
FTB-942
お問い合せ下さい   
納期: 
 
 
75-1200 ACFM Range; End Connections 4 MNPT (in)
Signal Conditioners (Order as a System for factory Scaling on FLSC-61 and FLSC-62, For Example: SYS/FTB-931/FLSC-62)
Accessories
Click to expand/minimize a list of what others bought with thePSR-24S
PSR-24S
お問い合せ下さい   
納期: 
 
 
Regulated power supply, US plug, 90-264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL
注: Comes complete with operator’s manual and NIST Certificate for air.

To order turbine meters with integral signal conditioners, specify model as a system such as : SYS/FTB-932/FLSC-62A. Omega will scale the signal conditioner with the appropriate calibration information from the turbine meter specified.

No other calibrations are available.

Compatible Meters: DPF701, DPF402, DPF70 with FLSC-AMP, DPF10, DPF500, FC20, 21, 22

Contact Flow Engineering Dept


 
We noticed you are from the US. Visit your local site for regional offers and live support.