The FL-1200 series has been discontinued. Please see the FLD100 Series as a possible alternative or contact our Flow Engineering department.
The FL-1200 flowmeters provide a low-cost means of flow rate indication.
They are designed for applications where precise accuracy requirements
for metering are not imperative. These meters are ideal for flow
measurement applications of: purge service, sealed oil systems, bearing
lubrication, cooling water indication and other associated applications.
SPECIFICATIONS SCALES Length: 65 mm (2.6") Graduations: Direct reading in GPM water or SCFM air
CONSTRUCTION Metering Tube: Borosilicate glass Float: 316 stainless steel Float Stops: stainless steel End Fittings and Tube Retaining Adaptor: Chrome-plated brass, 316 stainless steel Side Plates: Chrome-plated brass Packing Material: O-rings: Buna with Brass, FKM with stainless steel Packing: Neoprene with brass, FKM with stainless steel
RATINGS Pressure: 13.8 bar (200 psig) maximum Temperature: 121°C (250°F) maximum. Fluid temperatures below 0°C (32°F) will cause frosting of the glass metering tube. Connections: Horizontal female, 3/8 NPT Accuracy: ±10% full scale Repeatability: 0.5% full scale Dimensions: 214 H x 38 W x 116 mm D (8.44 x 1.5 x 4.56")
注:
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)