フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

High Accuracy Displacement Transducer/Motion Sensors (LVIT)

LDI-119

High Accuracy Displacement Transducer/Motion Sensors (LVIT) | LDI-119

High Accuracy Displacement Transducer/Motion Sensors (LVIT)

¥123,980 LDI-119-150-A010A

CE
  • Low Cost, Robust Construction
  • Contactless Operation Prevents Wearout from Dithering or Cycling
  • Excellent Stroke-to-Length Ratio
  • 19 mm (0.75") Diameter Housing Sealed to IP67
  • Wide Choice of Range: 25 to 200 mm (1 to 8") Full Scale
  • High Accuracy with Low Linearity Error
  • Radial Cable Exit with Swivel Rod Eye Ends
  • Designed to Operate Under Adverse Temperature, Vibration, Shock, and Humidity Conditions
変位測定器 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The LDI-119 Series LVIT (Linear Variable Inductive Transducer) position sensors are contactless devices designed for factory automation and a variety of industrial and commercial applications such as motor sport vehicles, automotive testing, solar cell positioners, wind turbine prop pitch and brakes, and packing equipment. With their compact device, superior performance, and excellent stroke-to-length ratio, the LDI-119 sensors are ideal for both industrial testing, laboratories, and OEM applications.

LDI-119 sensors are offered in 6 full scale ranges from 25 to 200 mm (1 to 8"). Operating from a variety of DC voltages, these sensors offer a choice of outputs and all include the field programmability calibration feature. LDI-119 products come with radial exiting cable and two swivel rod eye ends for easy installation.

The LDI series also include a larger body version, the LDI-127, for those applications needing a heavier duty unit.

Specifications
Analog I/Os:
    0 to 10V output with 12 to 30V input, 35 mA max;
    4 to 20 mA (3-wire) output with 18 to 30V input,
    60 mA max 75°C (167°F max)
Measuring Range: 25 to 200 mm (1 to 8") full scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/degree°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Aluminum
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
Anodized Aluminum Housing
0 to 10 Vdc output
LDI-119-025-A010A
¥101,596 (税込)
(税抜価格 ¥92,360)
納期: 2 週間
 
Linear sensor, 25 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-050-A010A
¥109,120 (税込)
(税抜価格 ¥99,200)
納期: 2 週間
 
Linear sensor, 50 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-075-A010A
¥122,485 (税込)
(税抜価格 ¥111,350)
納期: 6 週間
 
Linear sensor, 75 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-100-A010A
¥124,394 (税込)
(税抜価格 ¥113,085)
納期: 2 週間
 
Linear sensor, 100 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-150-A010A
¥136,378 (税込)
(税抜価格 ¥123,980)
納期: 4 週間
 
Linear sensor, 150 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-200-A010A
¥142,208 (税込)
(税抜価格 ¥129,280)
納期: 2 週間
 
Linear sensor, 200 mm range, 19 mm Al housing, radial cable, rodeye ends, 0 to 10 Vdc output
4 to 20 mA output
LDI-119-025-A020A
¥107,080 (税込)
(税抜価格 ¥97,345)
納期: 6 週間
 
Linear sensor, 25 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-050-A020A
¥114,620 (税込)
(税抜価格 ¥104,200)
納期: 6 週間
 
Linear sensor, 50 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-075-A020A
¥122,485 (税込)
(税抜価格 ¥111,350)
納期: 6 週間
 
Linear sensor, 75 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-100-A020A
¥131,384 (税込)
(税抜価格 ¥119,440)
納期: 2 週間
 
Linear sensor, 100 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-150-A020A
¥135,625 (税込)
(税抜価格 ¥123,295)
納期: 2 週間
 
Linear sensor, 150 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-200-A020A
¥134,640 (税込)
(税抜価格 ¥122,400)
納期: 2 週間
 
Linear sensor, 200 mm range, 19 mm Al housing, radial cable, rodeye ends, 4 to 20 mA output
300 Series Stainless Steel Housing
0 to 10 Vdc output
LDI-119-025-A010S
¥135,262 (税込)
(税抜価格 ¥122,965)
納期: 6 週間
 
Linear sensor, 25 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-050-A010S
¥144,441 (税込)
(税抜価格 ¥131,310)
納期: 6 週間
 
Linear sensor, 50 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-075-A010S
¥152,191 (税込)
(税抜価格 ¥138,355)
納期: 6 週間
 
Linear sensor, 75 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-100-A010S
¥161,365 (税込)
(税抜価格 ¥146,695)
納期: 6 週間
 
Linear sensor, 100 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-150-A010S
¥178,294 (税込)
(税抜価格 ¥162,085)
納期: 6 週間
 
Linear sensor, 150 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
LDI-119-200-A010S
¥195,228 (税込)
(税抜価格 ¥177,480)
納期: 6 週間
 
Linear sensor, 200 mm range, 19 mm SS housing, radial cable, rodeye ends, 0 to 10 Vdc output
4 to 20 mA output
LDI-119-025-A020S
¥135,262 (税込)
(税抜価格 ¥122,965)
納期: 6 週間
 
Linear sensor, 25 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-050-A020S
¥144,441 (税込)
(税抜価格 ¥131,310)
納期: 2 週間
 
Linear sensor, 50 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-075-A020S
¥152,191 (税込)
(税抜価格 ¥138,355)
納期: 6 週間
 
Linear sensor, 75 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-100-A020S
¥161,365 (税込)
(税抜価格 ¥146,695)
納期: 2 週間
 
Linear sensor, 100 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-150-A020S
¥178,294 (税込)
(税抜価格 ¥162,085)
納期: 6 週間
 
Linear sensor, 150 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
LDI-119-200-A020S
¥195,228 (税込)
(税抜価格 ¥177,480)
納期: 6 週間
 
Linear sensor, 200 mm range, 19 mm SS housing, radial cable, rodeye ends, 4 to 20 mA output
We noticed you are from the US. Visit your local site for regional offers and live support.