The LVR200 series has been discontinued. Please see the LVR500 as a possible alternative or contact our Flow Engineering department.
When your application calls for a
sealed tank, or the installation does
not lend itself to easy removal, the
LVR200 Series field-repairable
continuous level switches should be
considered. The entire stem and
face mount can be permanently
sealed to the vessel. Should
replacement of the reed switches
become necessary, unscrewing
the top mount and removing the
entire switch assembly can be
accomplished without
compromising the vessel’s interior
environment. The ability to easily
remove the LVR200 series from a
sealed tank allows most repairs to
be completed on-site. When
compared to conventional liquid
level switches, this field-repairable
continuous level switch eliminates
the need for tank depressurization
and reduces the chance of
environmental contamination.
SPECIFICATIONS: Resolution: 25.4 mm (1") Resistive Value: 220 Ω with
220 Ω per inch, standard Max Power: 0.125 W Lengths: 0.4 to 1.2 m
(16 to 48"), standard Wetted Materials: 316 SS stem and
fitting, polypropylene float Mounting: 2 NPT Polypropylene Float:
38.1 Dia. x 46.9 mm H (1.5 x 1.85") Temperature Range: -40 to 105°C
(-40 to 221°F) Pressure Range: 6.8 bar (100 psig) Output: 220 to 3520 Ω per inch, standard Specific Gravity of the Float: 0.75
注: Comes complete with operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.