フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Two-Wire Ultrasonic Level Transmitter

LVU-201A

Two-Wire Ultrasonic Level Transmitter | LVU-201A

Two-Wire Ultrasonic Level Transmitter

スクロールダウンし、全ラインアップをご覧ください

1 year warranty CE
  • Non-Contact Level Transmitter with 4 to 20 mA Output
  • Accurate and Reliable Level Measurement from 0.2 to 5.5 m (0.5 to 18')
  • Automatic Temperature Compensation
  • 8° Beam Allows Application in Restricted Environments
  • All-Plastic Construction
  • Pushbutton Calibration with Display
  • Microprocessor Logic Filtration Eliminates False Echo Signal Returns
  • Failsafe Intelligence Provides Echo Signal Loss Safety

商品説明

The LVU-201A has been replaced by LVU706 that performs the same function.


The LVU-201A 2-wire ultrasonic level transmitter is the compact solution for non-contact continuous level measurement in process vessels, storage tanks, and open channels. This loop-powered device provides accurate level measurement up to 5.5 m (18') and is the ideal choice for more challenging coating or scaling liquids, including sodium hydroxide, wastewater, resin, wax, liquor, and bleach.

An ultrasonic sound wave is pulsed 2 times per second from the base of the transducer. The sound wave reflects against the process medium below and returns to the transducer. The microprocessor-based electronics measure the time of flight between the sound generation and receipt, and translates this figure into the distance between the transmitter and process medium below.

SPECIFICATIONS
Range: 0.2 to 5.5 m (0.5 to 18')
Accuracy: ±0.25% of span
Resolution: 3 mm (0.125")
Frequency: 50 kHz
Pulse Rate: 2 pulses/second
Beam Width: 8° conical
Blocking Distance: 15.2 m (6") minimum
Display Type: 4-segment LCD
Display Units: In/cm
Supply Voltage: 12 to 32 Vdc
Max Loop Resistance: 600 Ω @ 24 Vdc
Signal Output: 4 to 20 mA
Signal Invert: 4 to 20 mA/20 to 4 mA
Calibration: Pushbutton
Mountable Gasket: FKM
Conduit Entrance: Single, 1.2 NPT
CE Compliance: EN61326 EMC
Failsafe Diagnostic: Reverts to 4 mA or 22 mA
Temperature Rating: -20 to 60°C (-4 to 140°F)
Temperature Compensation: Automatic over entire range
Pressure Rating: 30 psi @ 25°C, derated @1.667 psi per °C above 25°C
Enclosure Rating: NEMA 4X (IP66)
Enclosure Material: Polypropylene
Transducer Material: Polyvinylidene fluoride
Mounting threads: 2 NPT
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
LVU-201A
お問い合せ下さい   
納期: 
 
 
Ultrasonic 2-wire transmitter, loop powered (4 to 20 mA)
Accessories
SBG111956A
お問い合せ下さい   
納期: 
 
 
Intrinsic safety barrier for LVU-201A
LVCN-51
¥110,072 (税込)
(税抜価格 ¥100,065)
納期: 2 週間
 
Continuous relay controller with LED display
LV-BSRN-1/2
¥4,604 (税込)
(税抜価格 ¥4,185)
納期: 6 週間
 
Replacement black strain relief nut, 1/2" conduit connector opening
注: Comes complete with operator’s manual.


We noticed you are from the US. Visit your local site for regional offers and live support.