フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Three-Wire Ultrasonic Level Transmitter  - Discontinued

LVU-301, LVU-303

Three-Wire Ultrasonic Level Transmitter | LVU-301, LVU-303

Three-Wire Ultrasonic Level Transmitter

スクロールダウンし、全ラインアップをご覧ください

  • 8° Beam Allows Application in Restricted Environments
  • All Plastic Construction
  • LED Digital Display Indicates Level in Inches or Centimeters
  • Push Button Calibration For All User Set Points
  • Built-in 10A Relay May Be Configured For Alarm or Automatic Fill/Empty Operations
  • Fail-Safe Relay Logic Provides Echo and Power Loss Safety

商品説明

The {LVU-300} series has been discontinued. Please see the LVU2700 as a possible alternative or contact our Flow Engineering department.

The three-wire ultrasonic level transmitter is the compact solution for non-contact continuous level measurement in process vessels, storage tanks and open channels. The transmitter also features a built-in 10A relay which can be configured as an alarm on a single set point or latched on two different set points for automatic fill or empty operations. Industrial and municipal liquid examples include sodium hydroxide, wastewater, resin, wax, liquor and bleach. An ultrasonic sound wave is pulsed eight times per second from the base of the transducer. The sound wave reflects against the process medium below and returns to the transducer. The microprocessor based electronics measure the time of flight between the sound generation and receipt, and translates this figure into the distance between the transmitter and process medium below.
The surface of the level being measured must be free of fumes, vapors, foam and the surface must be flat; the signal may be lost if any of these conditions are present.

SPECIFICATIONS
Range: 0.5 to 24.5 feet
Accuracy: ± 0.25% of span
Resolution: 0.125” (3 mm)
Frequency: 50 kHz
Pulse rate: 8 pulses/second
Blocking distance: 6" minimum
Display type: 4 segment LED
Display units: Inch / cm
Supply voltage: 14-36 Vdc
Consumption: 200 mA
Current flow: Source / sink
Signal output: 4-20 mA, 12-36 Vdc
Signal averaging: Fast / slow
Calibration: Push button
Relay current: 10 amp
Relay output: 250 VAC, 10A, 1/2 hp, SPDT
Relay indication: ON / OFF status
Contact resistance: 30 milli½
Fail-safe diagnostic: Relay reverts to safe position
Temperature rating: -40 to 60°C, (-40 to 140°F)
Temp. compensation: Automatic over entire range
Pressure rating: 30 psi @ 25 °C., derated @1.667 psi per °C. above 25 °C.
Enclosure rating: NEMA 4X / IP65
Enclosure material: Polypropylene
Transducer material: PVDF
Mounting threads: 2 NPT

Please download PDF file below for full product specifications
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
Transmitters
Click to expand/minimize a list of what others bought with theLVU-301
LVU-301
お問い合せ下さい   
納期: 
 
 
Ultrasonic Three-Wire Transmitter,Sinking (4-20 mA)
  
LVU-303
お問い合せ下さい   
納期: 
 
 
Ultrasonic Three-Wire Transmitter, Sourcing (4-20 mA)
Accessories
  
LVCN-51
¥110,072 (税込)
(税抜価格 ¥100,065)
納期: 2 週間
 
Continuous Relay Controller with LED Display
Click to expand/minimize a list of what others bought with theDP24-E
DP24-E
お問い合せ下さい   
納期: 
 
 
1/8 DIN Panel Meter
Click to expand/minimize a list of what others bought with theTX4-100
TX4-100
¥10,603 (税込)
(税抜価格 ¥9,639)
納期: 2 週間
 
Sensor Wire 100 FT Spool
注: Comes complete with operator's manual.

The CE approved configuration complies with EN50082-2 immunity, EN55011 emission and EN 61010-1 safety standards.

The sourcing transmitter provides internal 4-20 mA excitation and should be used with a sinking device.

The transmitter with sinking output requires external excitation or should be used with a sourcing device, such as the LVCN-51 continuous relay controller.

(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)


Ordering Example: (1) LVCN-51 Proportional on/off controller, ¥100,065 
We noticed you are from the US. Visit your local site for regional offers and live support.