フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Intrinsically Safe Rugged Pressure and Temperature Datalogger

OM-CP-PRTEMP1000IS-A2-Srs

Intrinsically Safe Rugged Pressure & Temperature Datalogger
 | OM-CP-PRTEMP1000IS-A2-Srs

スクロールダウンし、全ラインアップをご覧ください

2 year warranty CE
  • Intrinsically Safe (IS) certification in accordance with the latest issue of FM3600 and FM3610.
  • Certified Intrinsically Safe for: Class 1 Division 1 Group ABCD,
  • Class 1 Division 2 Group ABCD, Temperature Class: T4A
  • Programmable Start Time
  • Real Time Operation
  • 303 Stainless Steel Enclosure
  • User-friendly
  • 1/4 inch NPT pressure port
データロガー - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The OM-CP-PRTEMP1000IS-A2 is a rugged pressure data logger that accurately monitors and records pressure and temperature at user programmable reading intervals. The OM-CP-PRTEMP1000IS-A2 has been certified as Intrinsically Safe (IS) certification in accordance with the latest issue of FM3600 and FM3610.


Certified Intrinsically Safe for:
  • Class 1 Division 1 Group ABCD
  • Class 1 Division 2 Group ABCD
  • Temperature Class: T4A

  • This certification makes the device ideal for uses in hostile environment applications such as air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure systems. The internal temperature sensor provides accurate temperature measurements without the need of a separate temperature data logger. OM-CP-PRTEMP1000IS-A2 can be started to take measurements as often as every two seconds, up to one reading every twelve hours. It will store up to 16,383 readings in its non-volatile memory. It uses a rugged stainless steel pressure strain gauge to accurately measure the pressure. The device comes standard with a common ¼ inch NPT fitting, which allows the logger to be adapted to almost any pressure fitting. There are many different pressure ranges available to suit most any application.



    PRESSURE

    Pressure Sensor

    Semiconductor strain gauge

    Pressure Range

    *See table below

    Pressure Resolution

    Calibrated Accuracy

    Pressure Response Time

    0.1 ms (10 to 90 %FSR)

    Repeatability

    ±0.5 %FSR; ±0.2 % typical


    Temperature

    Temperature Sensor Semiconductor
    Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
    Temperature Resolution 0.1 °C (0.18 °F)
    Calibrated Accuracy ±0.5 °C (0 °C to +50 °C)
    ±0.9 °F (+32 °F to +122 °F)

    General

    Adapter ¼ inch male NPT
    Memory 16,383 readings per channel;
    32,766 total readings
    Start Modes Software programmable immediate start or
    delay start up to six montds in advance
    Stop Modes Manual or Timed (specific date and time)
    Real Time Recording May be used with PC to monitor and record data in real time
    Reading Rate 1 reading every 2 seconds up to 1 reading every 12 hours
    Calibration Digital calibration through software
    Calibration Date Automatically recorded within device
    Battery Type 3.6 V lithium battery included, user replaceable
    Battery Life 1 year typical (1 minute reading rate @ 25 °C)
    Data Format Date and time stamped °C, °F, K, °R ; PSIA(g), inches, feet, mmHg, bar, Torr, kPa
    Time Accuracy ±1 minute/month at 25 °C
    Computer Interface OM-CP-IFC200 (interface cable required); 2,400 baud
    Operating System Compatibility Software programmable immediate start or
    delay start up to six montds in advance
    Software Compatibility Windows XP SP3/7/8/10
    Operating Environment -40 °C to +80 °C (-40 °F to +176 °F),
    0 %RH to 100 %RH
    Dimensions 6.4 in x 1.25 in dia. (163 mm x 32 mm dia.)
    Dimensions 6.4 in x 1.25 in dia. (163 mm x 32 mm dia.)
    Enclosure 303 Stainless Steel
    Approvals CE
    Certified Intrinsically Safe in accordance
    with the latest issue of FM3600 and FM3610
  • 1, Division 1 Group ABCD
  • 1, Division 2, Group ABCD
  • Temperature Class: T4A

  • *Range

    0-30 PSIA/PSIG

    0-100 PSIA/PSIG

    0-300 PSIA/PSIG

    0-500 PSIA/PSIG

    0-1000 PSIA

    0-5000 PSIA

    Accuracy

    0-30 PSIA/PSIG

    Resolution

    0.002 PSIA/PSIG

    0.005 PSIA/PSIG

    0.02 PSIA/PSIG

    0.05 PSIA/PSIG

    0.05 PSIA

    0.2 PSIA

    注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

    他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

    部品番号/Desc.
    注文数
    商品説明
      
    OM-CP-PRTEMP1000IS-A2-1-1000-A
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-1000 psia
      
    OM-CP-PRTEMP1000IS-A2-1-100-A
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-100 psia
      
    OM-CP-PRTEMP1000IS-A2-1-100-G
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-100 psig
      
    OM-CP-PRTEMP1000IS-A2-1-300-A
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-300 psia
      
    OM-CP-PRTEMP1000IS-A2-1-300-G
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-300 psig
      
    OM-CP-PRTEMP1000IS-A2-1-30-A
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-30 psia
      
    OM-CP-PRTEMP1000IS-A2-1-30-G
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-30 psig
      
    OM-CP-PRTEMP1000IS-A2-1-5000-A
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-5000 psia
      
    OM-CP-PRTEMP1000IS-A2-1-500-A
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-500 psia
      
    OM-CP-PRTEMP1000IS-A2-1-500-G
    お問い合せ下さい   
    納期: 
     
     
    IS Pressure & Temp Datalogger 0-500 psig
    Accessories
    Click to expand/minimize a list of what others bought with theOM-CP-BAT102
    OM-CP-BAT102
    ¥3,882 (税込)
    (税抜価格 ¥3,529)
    納期: 2 週間
     
    Replacement 3.6V lithium battery
    Click to expand/minimize a list of what others bought with theOM-CP-IFC200
    OM-CP-IFC200
    ¥33,970 (税込)
    (税抜価格 ¥30,882)
    納期: 2 週間
     
    USB Interface Cable (Required)
    We noticed you are from the US. Visit your local site for regional offers and live support.