This product is no longer available please see
OM-CP-PULSE101A as a direct substitute
The OM-CP-PULSE101 and
OM-CP-PULSE110 are low-cost
recording devices that will sense a
pulse input or contact closure from
external sources such as
transducers or pulse initiators (gas,
water, and electric meters) and
transform those inputs into
engineering units. In addition, these
dataloggers allow the user to store
user defined units such as gallons/
min into the device as well as scale
factors and offset values. This
enables the user to easily linearize
and scale any transducer that
provides a pulse or contact closure
output to any user required units
automatically. Once activated the
datalogger senses and records the
number of pulses/contact closures
that occur within adjacent “time bin”
periods. The bin period is selectable
from 1 second to over 24 hours. At
the end of each bin period, the total
number of pulses/counts within the
bin period is recorded. The datalogger
then starts another bin period and
continues until either the memory is
full or the test period has ended. Its
real time clock ensures that all data
is time and date stamped.
This is ideal
for recording events. The storage
medium is non-volatile solid state memory, providing maximum data
security even if the battery becomes
discharged. Its small size allows
it to fit almost anywhere. Data
retrieval is simple. Plug it into an
empty COM port and our easy-to-use
software does the rest. The software
converts your PC into a real time
strip chart recorder. Data can be
printed in graphical or tabular format
and can be exported to a text or
Microsoft Excel file.
SPECIFICATIONS Maximum Pulse Rate:
100 per second Minimum Pulse Width/Contact
Closure Time: 1.0 msec Input Signal:
TTL, internal pull-up, +30 V max Input Connection: Screw terminal Input Impedance: >1KΩ Recording Interval: 1 second to
12 hours selectable in software Real Time Recording: Device may
be used with PC to monitor and
record data in real time Green Visual Indicator: LED
flashes at selected reading rate Power: 3.6 V lithium battery included Battery Life: OM-CP-PULSE101:
1 year at 1 min reading rate
OM-CP-PULSE110:
up to 10 years (dependant on reading rate) Time Accuracy: ±1 minute/month
when RS-232 port is not in use Data Format:
Date and time stamped, pulse
counts, other units programmable
through software Weight: OM-CP-PULSE101: 30 g (1 oz)
OM-CP-PULSE110: 60 g (2 oz) Computer Interface: PC serial, RS-232C COM or USB
(interface cable required) Communications:
OM-CP-PULSE101: 2400 baud
OM-CP-PULSE110: 57600 baud Software:
WIN98/NT/2000/XP/VISTA 32-bit/7(32-bit); (VISTA/7 32-bit
version only; VISTA/7 64-bit are not supported) Operating Environment:
-40 to 80°C (-40 to 176°F)
5 to 95% RH non-condensing Dimensions:
OM-CP-PULSE101:
36 H x 56 W x 16 mm D
(1.4 x 2.2 x 0.6")
OM-CP-PULSE110:
43 H x 69 W x 20 mm D
(1.7 x 2.7 x 0.8")
注: Operator's manual, battery and RS-232 cable are included with the OM-CP-IFC200 Windows software (software sold separately). OM-CP-PULSE101 is CE approved only.