The OM-CP-THERMOVAULT140 series has been discontinued.
The OM-CP-THERMOVAULT140 is an extremely
high temperature thermal barrier designed for use
with the OM-CP-HITEMP140-5.25 and
OM-CP-HITEMP140-PT-1 data loggers. The thermal
barrier is made from a stainless steel enclosure
containing a Dewar flask and PTFE insulation. This
durable system can withstand temperatures up to
250°C (482°F) when completely submerged and
350°C (662°F) in dry heat applications (O-Ring
removed). The OM-CP-THERMOVAULT140 is built
for use in harsh applications that require extreme
temperature monitoring, such as with furnace profiling,
geothermal down-hole recording, autoclave validation,
and oven data logging.
The OM-CP-THERMOVAULT140 includes the thermal
barrier only. The OM-CP-THERMOVAULT140-5.25-TD
includes the thermal barrier as well as an
OM-CP-HITEMP140-5.25 data logger. The
OM-CP-THERMOVAULT140-PT-1 includes the thermal
barrier as well as an OM-CP-HITEMP140-PT-1 data
logger. The 133 mm (5.25") probe on the
OM-CP-HITEMP140-5.25 data logger is ideal for
ambient temperature monitoring, while the 559 mm (22")
flexible probe on the OM-CP-HITEMP140-PT-1 data
logger can be easily adjusted to measure hard-to-reach
locations, or even the internal temperature of a product.
Using the OM-CP Series data logger software, starting,
stopping and downloading the data logger is simple and
easy. Graphical, tabular and summary data is provided
for analysis and data can be viewed in °C, °F, K or °R.
The data can also be automatically exported to Excel®
for further calculations. Simply open the enclosure
and insert the data logger into the OM-CP-IFC400
docking station (sold separately). Using the software,
an immediate or delay start can be chosen, as well as
the reading rate. Select start to program the settings
and start the data logger. Place the cap back onto the
enclosure and screw it back together. The device is
ready to be deployed.
SPECIFICATIONS High Temperature Thermal Barrier Data Logging System (Stainless Steel Barrier and Data Logger) Operating Environment: Refer to the Time vs. Temperature Chart IP Rating: IP50 (no O-Ring), IP68 (O-Ring installed) Probe Junction/Type: 0.130" Thru-Hole, Compression Fitting (3/16" PTFE Sealing Ferrule) Enclosure Materials Enclosure: 300 Series stainless steel Seals: PTFE and silicone rubber Insulation: Dewar flask and PTFE Dimensions: 165 L x 63.5 mm dia (6.5 x 2.50") Minimum Recommended Probe Length: 133 mm (5.25") Weight: 1135 g (2.5 lb) Maximum Sustainable Pressure: 30 psia Maximum Sustainable Depth (inH2O): 21 m (70')
OM-CP-HITEMP140-5.25/OM-CP-HITEMP140-PT-1 Data Loggers (Without Stainless Steel Thermal Barrier) Temperature Sensor: 100 Ω Platinum RTD Temperature Range (Body): -40 to 140°C (-40 to 284°F) Temperature Measurement Range (Probe): -200 to 260°C (-328 to 500°F) Temperature Resolution: 0.01°C (0.02°F) Calibrated Accuracy: ±0.1°C (±0.18°F) [20 to 140°C (68 to 284°F)]; ±0.3°C (±0.54°F) [-20 to 19.99°C (-4 to 67.98°F)]; ±0.4°C (±0.72°F) [-40 to -20.01°C (-40 to -4.02°F)] Start Modes: • Software programmable immediate start • Delay start up to eighteen months in advance Stop Modes: • Manual through Software • Time (specific date and time) Real Time Recording: May be used with PC to monitor and record data in real time Memory: 32,700 readings Reading Rate: One second up to once every 24 hours Battery Type: 3.6V high-temperature lithium battery (included) Battery Life: 1 year typical [1 minute reading rate at 25°C (77°F)] Calibration: Digital calibration through software Calibration Date: Automatically recorded within device Data Format: Date and time stamped °C, °F, K, °R Time Accuracy: ±1 minute/month at 20 to 30°C (68 to 86°F) (RS232 cable not in use) Computer Interface: OM-CP-IFC400 USB docking station required (125,000 baud) Software: Windows XP SP3/Vista/7 and 8 (32- and 64-bit) Operating Environment: -40 to 140°C (-40 to 284°F), 0 to 100% RH Weight: 120 g (4.2 oz) Material: 316 stainless steel Dimensions OM-CP-HITEMP140-5.25 Body: 48 H x 25 mm dia (1.9 x 0.97") Probe: 133 L x 4.8 to 3.2 mm transitional dia (5.25 x 0.188 to 0.125") OM-CP-HITEMP140-PT-1 Body: 48 H x 25 mm dia (1.9 x 0.97") Probe Tip: 42 L x 3.2 mm dia (1.7 x 0.125") Flexible Probe Portion: 559 L x 1.6 mm dia (22 x 0.062")
注: Comes complete with 3.6V lithium battery. Operator’s manual and USB interface cable are included with the OM-CP-IFC400 software/docking
station package (required for data logger operation, sold separately). Ordering Example: (1) OM-CP-IFC400 Docking station (for single data logger) with software, USB cable and manual, ¥31,573