以下からオプションを選択:
(1)
Input and Output Type :DT : DC Displacement Transducer Input
LTC : Linearized Thermocouple Input
ITC : Non-Linearized Thermocouple Input
IP : RTD Input (Pt100 Ohm 2 or 3 Wire)
IC : RTD Input (Copper 2 or 3 Wire)
IN : RTD Input (Nickel 2 or 3 Wire)
IP4 : RTD Input (Pt100 Ohm 4 Wire)
IV : Voltage Input
IFI : Frequency Input
IMV : Millivolt Input
TC : 2-Wire Transmitter
PT : Potentiometer Input
WMV : Wideband Millivolt Input
WBS : Strain Gage Input
II : Current Input
WV : Wideband Voltage Input
IVI : Current Output
(2)
Input and Output Range :1 : Input ±1 Vdc (DT Only)
2 : Input ±2 Vdc (DT Only)
3 : Input ±3 Vdc (DT Only)
4 : Input ±4 Vdc (DT Only)
5 : Input ±5 Vdc (DT Only)
6 : Input ±6 Vdc (DT Only)
7 : Input ±7 Vdc (DT Only)
8 : Input ±8 Vdc (DT Only)
9 : Input ±9 Vdc (DT Only)
10 : Input ±10 Vdc (DT Only)
J1 : Thermocouple Type J 0 to 760°C (LTC Only)
J2 : Thermocouple Type J 100 to 300°C (LTC Only)
J3 : Thermocouple Type J 0 to 500°C (LTC Only)
K1 : Thermocouple Type K 0 to 1000°C (LTC Only)
K2 : Thermocouple Type K 0 to 500°C (LTC Only)
T1 : Thermocouple Type T -100 to 400°C (LTC Only)
T2 : Thermocouple Type T 0 to 200°C (LTC Only)
E : Thermocouple Type E 0 to 1000°C (LTC Only)
R : Thermocouple Type R 500 to 1750°C (LTC Only)
S : Thermocouple Type S 500 to 1750°C (LTC Only)
B : Thermocouple Type B 500 to 1800°C (LTC Only)
J : Thermocouple Type J -100 to 760°C (ITC Only)
K : Thermocouple Type K -100 to 1350°C (ITC Only)
T : Thermocouple Type T -100 to 400°C (ITC Only)
E : Thermocouple Type E 0 to 900°C (ITC Only)
R : Thermocouple Type R 0 to 1750°C (ITC Only)
S : Thermocouple Type S 0 to 1750°C (ITC Only)
B : Thermocouple Type B 0 to 1800°C (ITC Only)
C1 : Thermocouple Type C 350 to 1300°C (ITC Only)
N1 : Thermocouple Type N -100 to 1300°C (ITC Only)
N100 : Input -100 to 100°C (IP and IP4 Only)
100 : Input 0 to 100°C (IP and IP4 Only)
200 : Input 0 to 200°C (IP and IP4 Only)
600 : Input 0 to 600°C (IP and IP4 Only)
120 : Input 0 to 120°C (IC Only)
300 : Input 0 to 300°C (IN Only)
1A : Input ±1 V (IV and WV Only)
5A : Input ±5 V (IV and WV Only)
10A : Input ±10 V (IV and WV Only)
1B : Input ±1 V (IV and WV Only)
5B : Input ±5 V (IV and WV Only)
10B : Input ±10 V (IV and WV Only)
20A : Input ±20 Vdc (IV and WV Only)
40A : Input ±40 Vdc (IV and WV Only)
20B : Input ±20 Vdc (IV and WV Only)
40B : Input ±40 Vdc (IV and WV Only)
500 : Input 0 to 500 Hz (IFI Only)
1K : Input 0 to 1 KHz (IFI Only)
3K : Input 0 to 3 KHz (IFI Only)
5K : Input 0 to 5 KHz (IFI Only)
10K : Input 0 to 10 KHz (IFI Only)
25K : Input 0 to 25 KHz (IFI Only)
50K : Input 0 to 50 KHz (IFI Only)
100K : Input 0 to 100 KHz (IFI Only)
10A : Input ±10 mV Output ±5 Vdc (IMV and WMV Only)
50A : Input ±50 mV Output ±5 Vdc (IMV and WMV Only)
100A : Input ±100 mV Output ±5 Vdc (IMV and WMV Only)
10B : Input ±10 mV Output ±0-5 Vdc (IMV and WMV Only)
50B : Input ±50 mV Output ±0-5 Vdc (IMV and WMV Only)
100B : Input ±100 mV Output ±0-5 Vdc (IMV and WMV Only)
100 : Input 100 Ohm (PT Only)
1000 : Input 500 Ohm (PT Only)
1K : Input 1K Ohm (PT Only)
10K : Input 10K Ohm (PT Only)
1 : Input 4 to 20 mA Output 1 to 5 Vdc (TC Only)
2 : Input 4 to 20 mA Output 2 to 10 Vdc (TC Only)
1 : Full Bridge Input ±30 mV @ 10 V Exc (WBS Only)
2 : Full Bridge Input ±20 mV @ 10V Exc (WBS Only)
3 : Half Bridge Input ±20 mV @ 10V Exc (WBS Only)
4/20 : Input 4 to 20 mA (II Only)
0/20 : Input 0 to 20 mA (II Only)
B0 : Input 0 to 5 Vdc Output 0-20 mA (IVI Only)
A0 : Input ±5 Vdc (IVI Only)
B4 : Input 0 to 5 Vdc Ouput 4-20 mA (IVI Only)
A4 : Input ±5 Vdc Ouput 4-20 mA (IVI Only)
(3)
Additional Option (IC Only) :オプション選択がない場合 : None
-01 : 10 Ohm @ 0°C
-02 : 10 Ohm @ 25°C
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。
ご不明な場合は、カスタマーサービス(0120-040-572 もしくは jpesales@dwyeromega.com)へお問合せください。