OMYL-M41 (one pulse input channel) and OMYL-M42
(two pulse input channels) data loggers are designed to
measure potential-free (dry contact) pulses or voltage
signals up to 3V using the included OMYL-CS input
cable. With the optional OMYL-CP connection cable the
logger can be used for measuring signals up to 24V.
These data loggers are available with standard memory of
100,000 readings (OMYL-M41, OMYL-M42) or expanded
memory of 4 million readings (OMYL-M41-4M,
OMYL-M42-4M).
These devices are fully programmable allowing you to
set the data logger to record on one or two channels.
The incoming signal type (potential-free or voltage) can
be set using the included software.
These data loggers are best suited for operation with
counters, photoelectric sensors, revolution-counters,
make contact elements, switches and sensors such as
flow meters or energy consumption meters with pulse
output. Both data loggers can also be integrated into
the aerodynamic rain gauge OMYL-RG.
Once activated the data logger senses and records the
number of pulses/contact closures that occur within
adjacent “time bin” periods. The bin period is selectable
from 1 second to over 24 hours. At the end of each bin
period, the total number of pulses/counts within the
bin period is recorded. The data logger then
starts another bin period and continues until
either the memory is full or the test period
has ended.
The storage medium is non-volatile flash
memory so no data is lost if the battery
becomes discharged. Data logger setup as
well as data retrieval is accomplished using
the included standard OMYL-SOFT software.
Downloaded data is stored in the
OMYL-SOFT software as a text file for
viewing in third party software packages or
Microsoft Excel. The OMYL-SOFT standard
software does not include any graphing
functionality. Graphing and analyzing
downloaded data files requires the
OMYL-SOFT-PLUS version of the
software (sold separately)
SPECIFICATIONS
Number of Pulse Input Channels
OMYL-M41/OMYL-M41-4M: 1
OMYL-M42/OMYL-M42-4M: 2
Signal Input: Potential-free (dry contact) signals and low level pulses < 3 Vdc can be measured with the included OMYL-CS input cable; higher voltage level pulses up to 24 Vdc can be measured with the optional OMYL-CP input cable)
Maximum Input Voltage: 24 Vdc
Measuring Range
Potential Free (Dry Contact) Pulses
Pulse Count: 0 to 65,000 pulses
Pulse Rate: 0 to 100 Hz
Voltage Pulses
Pulse Count: 0 to 65,000 pulses
Pulse Rate: 0 to 1300 Hz
Reading Rate: 1 second to 24 hours
Start Modes: Immediate start, delayed start
Memory Capacity
OMYL-M41/OMYL-M42: 100,000 readings
OMYL-M41-4M/OMYL-M42-4M: 4 million readings
Memory Wrap Around: Yes (software configurable)
Battery: 3V lithium battery [standard temperature range battery (included), optional high temperature range battery]; user replaceable
Battery Life (Standard Temperature Range Battery): 4 years at 1 minute reading rate, 230 days at 10 second reading rate, 25 days at 1 second reading rate
LED Functionality: Integrated status LED indicates data logging status, low battery or alarm condition
Alarms: Software programmable high/low thresholds
Computer Interface: USB (interface cable included)
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Dimensions: 30 H x 50 mm dia (1.18 x 1.97")
Weight: 70 g (2.5 oz)
Enclosure: Robust, shock-proof POM, IP65
注: Comes complete with 3V lithium battery (standard temperature range), OMYL-CS pulse input connection cable for pulses < 3 V, 1.8 m (6') USB
interface cable and OMYL-SOFT software, and operator’s manual on USB stick.
製品マニュアル:
ダウンロード
Omega View Plus Software for OMYL Series