商品説明
This product line has been discontinued. For an alternate product, please see our wide selection of temperature and humidity loggers here.
The OMYL-T10 and OMYL-T10E are robust temperature
data loggers with IP65 enclosure. These data loggers
are available with standard memory of 100,000 readings
(OMYL-T10, OMYL-T10E) or expanded memory of
4 million readings (OMYL-T10-4M, OMYL-T10E-4M).
The OMYL-T10/OMYL-T10-4M have an internal
temperature sensor. The OMYL-T10E/OMYL-T10E-4M
have the temperature sensor fitted in an integral 100
mm steel probe. These data loggers are suited for a
variety of applications including environmental or climate
studies, meteorological research and also in clean
rooms and laboratories.
The storage medium is non-volatile flash memory so
no data is lost if the battery becomes discharged. Data
logger setup as well as data retrieval is accomplished
using the included standard OMYL-SOFT software.
Downloaded data is stored in the OMYL-SOFT software
as a text file for viewing in third party software packages
or Microsoft Excel. The OMYL-SOFT standard software
does not include any graphing functionality. Graphing
and analyzing downloaded data files requires the
OMYL-SOFT-PLUS version of the software (sold
separately).
SPECIFICATIONS
Sensor Type
OMYL-T10/OMYL-T10-4M: Internal temperature sensor
OMYL-T10E/OMYL-T10E-4M: Temperature sensor fitted in integral probe
Temperature Range: -30 to 70°C (-22 to 158°F) with standard lithium battery (included); -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Resolution: 0.01°C (0.02°F)
Accuracy: See Chart on PDF
Reading Rate: 1 second to 24 hours; 2 Hz, 4 Hz, 8 Hz, 16 Hz, 32 Hz in fast mode
Start Modes: Immediate start, delayed start
Memory Capacity
OMYL-T10, OMYL-T10E: 100,000 readings
OMYL-T10-4M, OMYL-T10E-4M: 4 million readings
Memory Wrap Around: Yes (software configurable)
Battery: 3V lithium battery [standard temperature range battery (included), optional high temperature range battery]; user replaceable
Battery Life (Standard Temperature Range Battery): 4 years at 1 minute reading rate, 230 days at 10 second reading rate, 25 days at 1 second reading rate
LED Functionality: Integrated status LED indicates data logging status, low battery or alarm condition
Alarms: Software programmable high/low thresholds
Computer Interface: USB (interface cable included)
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Dimensions
OMYL-T10, OMYL-T10-4M: 30 H x 50 mm dia (1.18 x 1.97")
OMYL-T10E, OMYL-T10E-4M: 30 H x 50 mm dia (1.18 x 1.97") with 100 L x 4 mm dia probe (3.94 x 0.16")
Weight: 70 g (2.5 oz)
Enclosure: Robust, shock-proof POM, IP65
注: Comes complete with 3V lithium battery (standard temperature range), 1.8 m (6') USB interface cable,