  • Very High Accuracy: ±0.015% of Reading
  • Very High Resolution: 0.001 mA
  • Auto Step and Ramp Function
  • % Error Function— Eliminates Manual Error Calculation
  • Extended Adjustment Range—Digital Knob and User-Selectable Decade Output Allow Large and Incremental (0.001 mA Step) Output Changes
  • Reads 0 to 28 Vdc
  • Built-In 250 Ohm Resistor Facilitates Calibration of Hart™ Devices
  • Remote Calibration Through Automatic Step and Ramp Functions
  • Loop Power Measurement Capability
  • Simulates, Powers, and Measures 2-Wire Transmitters
  • 5 Preset Outputs (4, 8, 12, 16, 20 mA)
  • Fuseless Input Protection Up to 250 Vac
表示器 / 記録装置 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

With an accuracy of 0.015% of reading, 0.001 mA resolution, and 1 microamp step resolution, the PCL120 has the highest precision in its class. Other features that make the PCL120 stand out include a "% error" function, which eliminates manual error calculation and allows the display of actual versus ideal error at any calibration point. The PCL120 can simulate, power, and measure 2-wire transmitters. Its automatic step and ramp functions enable remote calibration of 4 to 20 mA devices.

The PCL120 has many innovative, powerful features that make calibration easy. A few clearly marked keys give the user access to the full functionality of the unit. The STEP and RAMP output modes automate either a discrete 4-8-12-16-20-16-12-8-4 mA stair step output or 2 speeds of a linear 4-20-4 mA ramp output. Pressing the AUTO key (1) activates this time-saving function. To further aid remote calibration, the PCL120 features a minimum/maximum value recall function. In the measure mode, holding the AUTO(/MAX) key (1) gives a direct readout of the maximum value, while holding the 25%(/MIN) key (4) gives a direct readout of the minimum value. Holding the % ERROR key (2) while turning the large knob provides instant feedback on the difference between the ideal and actual current values required for a given device response. This tells the user whether the device is within its accuracy range. No further calculations are necessary. A LOOP POWER key (3) provides instant 24 Vdc loop power output. The 25% (4) key provides instant outputs of 4, 8, 12, 16, and 20 mA loop current, with increments occurring each time the key is pushed.

SPECIFICATIONS (25°C Unless Otherwise Noted)
Input
Current Range: 0 to 24 mA; -25 to 125%
Voltage (Reading): 0 to 28 Vdc
Input Protection: Fuseless up to 250 Vac
Output
Source/Simulate Range: 0 to 24 mA; -25 to 125%
Drive Capability:
    Without HartTM: 1200 O
    With HartTM: 950 O
Loop Supply Voltage: 24 Vdc
Range Select: Decade; incremental in 0.001 mA steps
Resolution: 1 µA
Accuracy: ±0.015% of reading ±2 µA
Environmental
Operating Temperature:
-10 to 55°C (14 to 131ºF)
Storage Temperature: -20 to 70°C (-4 to 158ºF)
Power Requirement: 9 Vdc
Battery: One 9 V (included)
AC Adaptor: Optional
Mechanical Dimensions (Without Boot): 144.7 H x 80 W x 3.63 mm D (5.7 x 3.15 x 1.43")
Weight: 340 g (12 oz)
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)

他のお客様はこのような商品も購入しています。: このアイコンをクリックすると、このモデルを購入した他のお客様の購入商品リストが表示されます.

部品番号/Desc.
注文数
商品説明
  
PCL120
お問い合せ下さい   
納期: 
 
 
Precision loop calibrator
Click to expand/minimize a list of what others bought with thePCL-ACA
PCL-ACA
お問い合せ下さい   
納期: 
 
 
120 Vac power adaptor (PCL422A-BATT required)
  
PCL422A-BATT
¥8,894 (税込)
(税抜価格 ¥8,085)
納期: 2 週間
 
9 V NiCad battery
注: Comes with test leads, 9V battery, calibration certificate, flexible protective sleeve, and complete operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.