フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

 - Discontinued Fast Response Pressure Transducer

PX105-5V Series

Fast Response Pressure Transducer | PX105-5V Series

Fast Response Pressure Transducer

スクロールダウンし、全ラインアップをご覧ください

  • Accuracy: ±0.5% Typ
  • Fully Calibrated and Temperature Compensated
  • Internal Voltage Regulation
  • Interchangeable Unit to Unit ±1%
  • Computer Trimmed to Insure Accuracy and Repeatability
  • Long Term Stability ±1%
  • Operating Temperature Range -55 to 125°C
  • Rugged Temperature Resistant Valox Case and Connector

商品説明

The PX105 series has been discontinued. Please see the PX309 as a possible alternative or contact our Pressure Engineering department.

SPECIFICATIONS
Excitation: 8 to 20 Vdc at 15 mA
Output: 1 to 6 Vdc
Accuracy: ±1% FS maximum
Linearity:
    <50 psi: ±0.5% FS
     ≥50 psi: ±0.2% FS
Hysteresis: ±0.25% FS
Zero Balance: ±1% FS typical; ±3% full scale maximum
Frequency Response: 3 dB at 1.5 kHz
Compensated Temperature Range: 0 to 85°C (32 to 185°F)
Thermal Zero Effect: ±0.02% rdg/°C (±0.01% rdg/°F)
Proof Pressure: 2x FS
Burst Pressure: 5x FS minimum
(6, 15, 25 psig = 20x FS)
Gages: Piezoresistive
Diaphragm/Port Material: 300 Series SS (silver, copper,nickel, cadmium brazed)
Electrical Connection: CX106-4, included
Weight: 114 g (4 oz)
注: Typical media for the PX105 include oil, gases, saline solutions, ammonia, freon, hydraulic fluids, alcohol, acid and gasoline