SPECIFICATIONS Excitation: 5 Vdc Output Range: Range @ 50 psi = 1 mV/V; range >100 psi: 2 mV/V Bridge Resistance: 350 Ω nominal Zero Balance: ±1.0% of FSO Accuracy: 1.0% linearity and hysteresis combined; calibrated at 0%, 50%, 100%, 50%, 0% Repeatability: 0.1% of FSO Operating Temperature Range: -54 to 121°C (-65 to 250°F) Compensated Temperature Range: 16 to 71°C (60 to 160°F) Thermal Effects: Zero: ±0.01% FS/°F Span: ±0.02% FSO/°F Proof Pressure: 150% of capacity Burst Pressure: 500% of capacity or 10,000 psi, whichever is less Electrical Connections: PTIH-10-6P connector Mating Connector: PT06F10-6S-R (not included) Pressure Connection: ¼-18 NPT Wetted Parts: 17-4 PH stainless steel Weight: 50 g (0.55 oz)
注: Metric Ranges Available - Consult Engineering. 6 wire cable is only required when using input sense leads. Ordering Example: (1) PT06F10-6S mating connector (sold separately), ¥7,019 plus (1) PX61C1-100AV is a 0-100 psi Absolute Pressure transducer transducer with PT1H-10-6P connector and 1/4 -18 NPT male fitting, ¥128,700, ¥7,019 + 128,700 = ¥135,719