フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

High Pressure Solenoid Valve

SVH-110

High Pressure Solenoid Valve | SVH-110 |Fuel Cell Valve | High Pressure Valve | SVH-110

¥167,805 SVH-111

1 year warranty
  • Stainless Steel Construction
  • NEMA 4 and 7
  • Pressures up to 10,000 psi (Depending on Model)
電磁弁 (バルブ) - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The SVH-110 Series direct acting solenoid valves are normally closed valves that open when energized and close when de-energized. When the coil is energized the plunger lifts the piston off the valve seat, opening the valve. Upon de-energizing the coil, a spring closes the piston to seat it. The normally open valve operates similarly, closing when energized and opening when de-energized. No minimum pressure is required. The SVH-110 Series are used to control the flow of high pressure air, water, hydrogen, nitrogen and other gases or light liquids compatible with materials of construction. They are also suitable for cryogenic applications.

Specifications
Materials of Construction
Fluid Shipping Weight: 48 oz (3 lb)
Temperature: -212 to 204°C (-350 to 400°F)
Valve Body: 316 SS
Piston/Seal: 303 SS/FEP
O-Ring Seal: FEP
Spring: 302 SS
Plunger: 430 SS
Bonnet: 316 SS/430 SS
Bonnet Retainer: 430 SS
Port Connections: ¼ NPT
Cv: 0.005 (SVH-111), 0.02 (SVH-112)
Electrical
Power: 22 Watts
AC Inrush: 2.5 Amp @ 120 Vac
AC Holding: 0.2 Amp at 120 Vac
Insulation: Class “H”
Duty: Continuous
Enclosure: NEMA 4 and 7(optional)
Connection: ½ NPT, 457 mm (18") leads
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
SVH-111
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 120 Vac, Port Diameter mm (inch) 0.48 (0.019), Maximum Pressure 10,000 psig
SVH-111-24A
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 24 Vac, Port Diameter mm (inch) 0.48 (0.019), Maximum Pressure 10,000 psig
SVH-111-240A
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 240 Vac, Port Diameter mm (inch) 0.48 (0.019), Maximum Pressure 10,000 psig
SVH-111-24D
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 24 Vdc, Port Diameter mm (inch) 0.48 (0.019), Maximum Pressure 5000 psig
SVH-111-120D
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 120 Vdc, Port Diameter mm (inch) 0.48 (0.019), Maximum Pressure 5000 psig
SVH-112
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 120 Vac, Port Diameter mm (inch) 0.81 (0.032), Maximum Pressure 4000 psig
SVH-112-24A
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 24 Vac, Port Diameter mm (inch) 0.81 (0.032), Maximum Pressure 4000 psig
SVH-112-240A
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 240 Vac, Port Diameter mm (inch) 0.81 (0.032), Maximum Pressure 4000 psig
SVH-112-24D
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 24 Vdc, Port Diameter mm (inch) 0.81 (0.032), Maximum Pressure 2000 psig
SVH-112-120D
¥184,586 (税込)
(税抜価格 ¥167,805)
納期: 5 週間
 
Coil Voltage 120 Vdc, Port Diameter mm (inch) 0.81 (0.032), Maximum Pressure 2000 psig
注: Comes complete with operator’s manual.

For units for Hydrogen service (Helium leak test), add suffix “-HY” to the model number; add $32.00 to the price.

For Normally Open valve configuration, add suffix "-NO” to the model number (Only available on AC powered units); add $53 to the price.

For Oxygen cleaned units, add suffix “-OX” to the model number; add $53 to the price.

For units with Straight Thread J1926 with O-ring seal, add suffix “-ST” to the model number; add $53 to the price.

For units with a NEMA 7 enclosure, add suffix "-NEMA7” to the model number, add $100 to the cost.


We noticed you are from the US. Visit your local site for regional offers and live support.