フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Vapor and Gas Actuated Thermometers, Panel & Surface Mount - Discontinued

VA and GA Series

Vapor and Gas Actuated Thermometers | VA and GA Series

Vapor and Gas Actuated Thermometers

スクロールダウンし、全ラインアップをご覧ください

  • Accuracy ±1 Scale Division or 1% Scale for Gas
  • Brass Movement with Precision Gearing
  • White Dial with Black Graduations
  • Phosphor Bronze Bourdon Tube
ガラス温度計 / バイメタル温度計 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

This item is no longer available. Please contact Customer Service for further assistance.

Remote vapor- and gas-actuated thermometers are manufactured to the highest standards for a wide range of uses and can be fitted into almost any temperatureindicating application. These instruments are ideal for remote reading, such as panel installations, with capillary lengths of 1 to 100'. Vapor, or more precisely vaporized liquid, thermometers will give excellent readings, provided the temperature being measured is above or below ambient temperature. Vapor instruments also have progressive graduations and are best read in the upper 2/3 of the dial range. Many ranges are available between -40 to 232°C (-40 to 450°F), and care should be taken to select a range that will locate the operating temperatures within the upper 2/3 of the dial range.

OMEGA gas-actuated thermometers combine advanced gas coil technology with a state-of-the-art gas absorbent (Class IV) thermal system, producing a superior temperature measurement instrument that can be fitted to a wide variety of applications. Gas-actuated thermometers have an advantage over vapor-actuated thermometers in that they are more accurate over the full range. They also operate at higher and lower ranges than vapor-actuated thermometers.

The linear dial on all OMEGA gas thermometers provides a consistent 1% accuracy across the full span of each range. This, combined with over 20 Fahrenheit and dual ranges, from -196 to 649°C (-320 to 1200°F), provides complete coverage of all normal temperature requirements.

SPECIFICATIONS
Dial Sizes: 2", 2½", 3½", 4½"
Dial: Aluminum with white finish and black markings
Pointer: Furnished standard adjustable
Movement: Brass with precision gearing
Bourdon Tube: Vapor-phosphor bronze
Gas: Nitrogen in nispan coil
Accuracy:
    Vapor: ±1 scale division
    Gas: ±1% of scale
Process Connection: Plain bulb, ½NPT union; or thermowell
Note: thermowells must be used whenever the bulb would be exposed to pressure, fluid velocity, or corrosive media.
Window: Polycarbonate STD; glass available on all models
Bulb: Stainless steel or copper; bulb O.D. 3/8" on plain bulbs, 7/16" with threads. Bulb lengths from 2½" to 7 7/8" depending on capillary length.
Capillary: Copper, copper with bronze braid armor; stainless steel with stainless steel armor; capillary lengths 1 to 100' (standard length, 5')
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
GA-25FR-FN-E-30-L2
お問い合せ下さい   
納期: 
 
 
Gas Actuated Thermometer
GA-35RB-FL-E-05-J1
お問い合せ下さい   
納期: 
 
 
Gas Actuated Thermometer
VA-35RB-60-D-3-M2
お問い合せ下さい   
納期: 
 
 
Vapor Actuated Thermometer
VA-45RR-20-E-5-J1
お問い合せ下さい   
納期: 
 
 
Vapor Actuated Thermometer

クイックオーダー

部品番号
注文数
部品番号
注文数


部品番号ビルダー

下記から仕様構成を選択し、ご注文ください
以下からオプションを選択:


(1) Style :
VA : Vapor Actuated Thermometer
GA : Gas Actuated Thermometer

(2) Case Style and Size :
20FR : Front Flange (Panel Mount) style.Dial 2 in. Case stainless steel. Connection location rear
25FR : Front Flange (Panel Mount) style. Dial 2 1/2 in. Case stainless steel. Connection location rear
35FR : Front Flange (Panel Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
45FR : Front Flange (Panel Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location rear
45FL : Front Flange (Panel Mount) style. Dial 4 1/2 in. Case black aluminum (hinge ring type). Connection location lower rear
20UR : U-Clamp (Panel Mount) style. Dial 2 in. Case stainless steel. Connection location rear
25UR : U-Clamp (Panel Mount) style. Dial 2 1/2 in. Case stainless steel. Connection location rear
35UR : U-Clamp (Panel Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
20RR : Rear flange (Surface Mount) style. Dial 2 in. Case stainless steel. Connection location rear
35RR : Rear flange (Surface Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
35RB : Rear flange (Surface Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location bottom
45RR : Rear flange (Surface Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location rear
45RB : Rear flange (Surface Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location bottom
45TB : Rear flange (Surface Mount) style. Dial 4 1/2 in. Case Phenolic. Connection location bottom (turret)

(3) Temperature Range (ranges 300°F or above for vapor-actuate and all gas-actuated models only offered with stainless steel systems.) :
20 : -40 to 60°F (VA Range only)
21 : -40 to 60°F (-40 to 15°C) (VA Range only)
30 : -40 to 110°F (VA Range only)
31 : -40 to 110°F (-40 to 40°C) (VA Range only)
32 : -20 to 120°F (VA Range only)
33 : -20 to 120°F (-30 to 50°C) (VA Range only)
72 : 0 to 180°F (VA Range only)
73 : 0 to 180°F (-20 to 80°C) (VA Range only)
49 : 0 to 150°F (VA Range only)
79 : 0 to 150°F (-15 to 65°C) VA Range only)
80 : 20 to 220°F (VA Range only)
81 : 20 to 220°F (0 to 105°C) (VA Range only)
50 : 40 to 240°F (VA Range only)
51 : 40 to 240°F (0 to 115°C) (VA Range only)
56 : 0 to 250°F (VA Range only)
57 : 0 to 250°F (-20 to 120°C) (VA Range only)
60 : 30 to 300°F (VA Range only)
61 : 30 to 300°F (0 to 150°C) (VA Range only)
68 : 100 to 350°F (VA Range only)
66 : 100 to 350°F (40 to 175°C) (VA Range only)
FB : -320 to 100°F (GA Range only)
DB : -320 to 100°F (-200 to 40°C) (GA Range only)
FE : -120 to 120°F (GA Range only)
DE : -120 to 120°F (-85 to 50°C) (GA Range only)
FG : -40 to 180°F (GA Range only)
DG : -40 to 180°F (-40 to 80°C) (GA Range only)
FH : 0 to 120°F (GA Range only)
DH : 0 to 120°F (-15 to 50°C) (GA Range only)
FJ : 60 to 120°F (GA Range only)
DJ : 60 to 120°F (15 to 50°C) (GA Range only)
FL : 20 to 240°F (GA Range only)
DL : 20 to 240°F (-5 to 110°C) (GA Range only)
FN : 0 to 300°F (GA Range only)
DN : 0 to 300°F (-10 to 150°C) (GA Range only)
FP : 50 to 550°F (GA Range only)
DP : 50 to 550°F (10 to 29°C) (GA Range only)
FR : 50 to 750°F (GA Range only)
DR : 50 to 750°F ( 0 to 400°C) (GA Range only)
FT : 400 to 1200°F (GA Range only)
DT : 400 to 1200°F (200 to 650°C) (GA Range only)
70 : 200 to 450°F (GA Range only)
71 : 200 to 450°F (100 to 230°C) (GA Range only)

(4) Capillary and Bulb :
A : Capillary and bulb material copper.
C : Capillary and bulb material copper. Capillary protection bronze braid
D : Capillary and bulb material 316 SS.
E : Capillary and bulb material 316 SS. Capillary protection SS armor

(5) Capillary Length (For custom length contact our sales team for pricing) :
05 : 5 Feet
10 : 10 Feet
25 : 25 Feet

(6) Process Connection :
J1 : Connection type none (plain bulb)
K2 : Connection type 1/2 NPT union. Material Brass
L2 : Connection type 1/2 NPT union. Material 316 SS
M2 : Connection type 1/2 NPT union jam nut and bendable extension. Material 316 SS
J2 : Connection type Jam nut only (required with thermowell). Material Brass
J3 : Connection type Jam nut only (required with thermowell). Material 316 SS

(7) Lens :
オプション選択がない場合 : None
-Glass : Glass lens
-Poly : Polycarbonate Lens
注: 有効な部品番号については、「商品仕様(PDF)」を参照ください。
ご不明な場合は、カスタマーサービス(0120-040-572 もしくは jpesales@dwyeromega.com)へお問合せください。