フリーダイヤル 0120-769-103
Emailjpesales@dwyeromega.com

Wind Monitoring Station with Analog Outputs

WMS-20

Wind Monitoring Station with Analog Outputs, Models WMS-21, WMS-22A, WMS-22B | WMS-20

スクロールダウンし、全ラインアップをご覧ください

1 year warranty
  • 0 to 100 mph Measurement Range
  • Reed Switch Transducer
  • 1 mph or 3% Accuracy
環境 / 気象測定器 - 関連する商品を探す
(見つからない場合はカスタマーサービスにご連絡ください)

商品説明

The WMS-20 series consist of three individual wind monitor stations. The WMS-21 is a microprocessor based wind alarm station. It sounds an alarm buzzer and controls the operation of two electrical circuits whenever wind speed reaches either of two independent setpoints. An LCD display provides a readout of the measured wind speed and is also used to set the value of the setpoints. Self-contained relays for each alarm point can be used to actuate external devices such as air samplers or sirens.

The WMS-23 series monitors wind speed and direction. Each parameter is converted into a 4 to 20mA signal for use by process controllers or monitoring systems. Two versions are offered, WMS-23S measures wind speed only, while the WMS-23 measures both wind speed and direction.

SPECIFICATIONS
WMS-21(Wind Speed)
Measurement Range:
0 to 100 mph
Transducer Type: Reed switch
Avg Speed Resolution: 0.1 mph
Threshold Speed: 0.8 mph
Measurement Accuracy: 1 mph or 3%
Controls: Protected push-button for run, or set variables, select menu items, increment and decrement alarm values
Alarm On/Off Delay Range: 0 to 99 sec
Contact Ratings: 3 A SPDT @ 24 Vdc
Display: 2 line x 16 character LCD
Character Size: 3 x 8 mm
Setpoint 1 and 2: LED
Supply Voltage: 12 Vac or Vdc
Supply Current: 50 mA, 5 mA nominal
Operating Temperature: -20 to 50ºC (-4 to 122°F)
Dimensions:
    Anemometer: 114.3 H x 215.9 W mm (4.5 x 8.5")
    Sensor Cable Length: 12 m (40'), supplied
    Electronics Enclosure Size: 119.3 H x 198.1 W x 88.9 D mm (4.7 x 7.8 x 3.5")

WMS-23 (Wind Speed and Direction), WMS-23S (Wind Speed)
Measurement Range:
0 to 100 mph
Transducer Type: Reed switch
Threshold Speed: 0.8 mph
Measurement Accuracy: 1 mph or 3% WMS-23 Only (Wind Direction)
Azimuth Accuracy: ± 3%
Mechanical Range: 0 to 360°
Potentiometer Gap:
Threshold: 1.2 mph
Measurement Range: 0 to 360°
Current Loop:
    Output Span: 4 to 20 mA
    Proportioned: 0 to 100 mph, 0 to 360º
    Circuit Time Constant: 1 sec
    2-Wire Loop Interface: Screw terminal block
    Supply Voltage: 8 to 30 Vdc
    Operating Temperature: -40 to 40ºC (-40 to 104ºF)
Dimensions:
    Anemometer and Vane: 305 H x 254 W mm (12 x 10")
    Anemometer Only: 114.3 H x 215.9 W mm (4.5 x 8.5")
    Sensor Cable Length: 12 m (40'), supplied
    Electronics Enclosure Size: 114.3 H x 114.3 W x 63.5 D mm (4.5 x 4.5 x 2.5")
注文する (部品番号ビルダーより掲載以外の製品もご選択いただけます)(注文数を入力の上、"カートに追加"をクリックしてください)
部品番号/Desc.
注文数
商品説明
WMS-23S
¥328,383 (税込)
(税抜価格 ¥298,530)
納期: 2 週間
 
Wind speed 4 to 20 mA output
WMS-21
¥354,398 (税込)
(税抜価格 ¥322,180)
納期: 2 週間
 
Dual Setpoint Wind Station
WMS-23
¥374,699 (税込)
(税抜価格 ¥340,635)
納期: 4 週間
 
Wind speed/direction 4 to 20 mA outputs
注: Units Supplied with sensor cable and operator’s manual.
 

製品マニュアル:

ダウンロード Wind Station
ダウンロード Current Loop Wind Sensor
We noticed you are from the US. Visit your local site for regional offers and live support.