Interfaces to Contact Closures or TTL Inputs up to 30 V
User-Friendly
商品説明
This product is no longer available please see
OM-CP-STATE101A as a direct substitute
The OM-CP-STATE101 and
OM-CP-STATE110 are miniature,
low-cost, recording devices which
sense input transitions or contact
closures from external sources such
as transducers and/or state initiators
and records the time and input state
of the device when a transition
occurs. The device can store up to
13,107 time stamped state changes.
Once activated the data logger
senses and records transition or
state changes at the input. The
device’s real-time clock ensures that
all data is time and date stamped.
The storage medium is non-volatile
solid state memory, providing
maximum data security even if the
battery becomes discharged. The
device can be started and stopped
directly from your computer and its
small size allows it to fit almost
anywhere. Data retrieval is simple.
Simply plug it into an empty COM
port and our user-friendly software
does the rest.
Specifications Input Connection: Removable
screw terminal Input Low: < 0.4 Input High: > 2.7 V Input Range: 0 to 30 Vdc
(see table for the recommended
duty cycles for a high input over a
one minute interval) Input Impedance: > 1 K Ohm Time Resolution: 1 second
(reading rate dependent) Visual Indicator: LED flashes at
selected reading rate Real Time Recording: May be
used with PC to monitor and record
data in real time Memory: 13,107 readings Reading Interval: 1 reading every
second to 1 every 12 hours Start Time:Software
programmable start time and date,
up to six months in advance Battery Life:
OM-CP-STATE101:
1 year typical life at 25°C
OM-CP-STATE110:
10 years at 25°C Power:
3.6 V lithium battery included Data Format: Date and time
stamped state changes (on/off) Time Accuracy: ±1 minute/month
at 20°C (RS-232 cable not in use Computer Interface:
PC serial, RS-232C COM or USB
(Interface cable required) Communications:
OM-CP-STATE101: 2400 baud
OM-CP-STATE110: 57600 baud Software:
WIN98/NT/2000/XP/VISTA 32-bit
(VISTA 32-bit version only;
VISTA 64-bit is not supported) Operating Environment:
-40 to 80°C, (-40 to 176°F)
5 to 95% RH non-condensing Dimensions:
OM-CP-STATE101:
36 H x 64 W x 16 mm D
(1.4 x 2.5 x 0.6")
OM-CP-STATE110:
43 H x 69 W x 20 mm D
(1.7 x 2.7 x 0.8") Weight:
OM-CP-STATE101: 30 g (1 oz);
OM-CP-STATE110: 60 g (2 oz)
注: Operator’s manual and RS-232 cable are included with the OM-CP-IFC110 Windows software (software sold separately). OM-CP-STATE101 is CE approved only. Ordering Example: (1) OM-CP-IFC200 Windows software and 1.8 m (6') USB interface cable, ¥30,882