Simple Compact Sensor with Target Calibration and LED Status Indicators
4 Measurement Ranges up to 8 m (26') with 1 or 2" (25 to 50 mm) Transducer Mounting
5 cm (2") Minimum Beam Width For Applications With Restricted Space
5 cm (2") Deadband Optimizes the Filling Capacity of Small Vessels
PC/ABS Enclosure is Rated NEMA 6 (IP67) with Optional NEMA 4X (IP65) Available
Fail-Safe Intelligence with Diagnostic Feedback for Easy Troubleshooting
商品説明
The LVU100 Series has been discontinued. Please see the
LVU800 Series as a possible alternative or contact our Flow Engineering department.
The LVU100 Series is a general purpose 2-wire ultrasonic
transmitter. It provides non-contact level measurement up to 8 m (26'),
and is well suited for handling ultrapure, corrosive, slurry or waste
liquids. The LVU100 Series transmitter is often used in atmospheric
bulk storage, day tank, waste sump, process vessel, IBC tote,
55-gallon drum and waste sump applications. Media examples
include acetic acid and resin.
SPECIFICATIONS Range: LVU104: 5 cm to 1.2 m (2" to 4') LVU109: 10 cm to 3 m (4" to 9.8') LVU116: 10 cm to 5 m (4" to 16.4') LVU126: 20 cm to 8 m (8" to 26.2') Accuracy: LVU104: 3 mm (0.125") LVU109/116/126: ±0.2% of span in air Resolution: LVU104/109: 0.5 mm (0.019") LVU116/126: 1 mm (0.039") Beam Width: LVU104 /109: 5 cm (2") dia. LVU116/126: 7.6 cm (3") dia. Deadband: LVU104: 5 cm (2") LVU109/116: 10 cm (4") LVU126: 20 cm (8") LED Indication: Power, calibration and diagnostics Memory: Non-volatile Supply Voltage: 12 to 28 Vdc Loop Resistance: 500 Ω @ 24 Vdc Signal Output: 4 to 20 mA, 2-wire Signal Invert: 4 to 20 mA or 20 to 4 mA Calibration: Target, calibration wire Fail-Safety: Reverts to 22 mA Process Temperature: -20 to 60°C (-4 to 140°F) Temperature Compensation: Automatic Electronics Temperature: -40 to 71°C (-40 to 160°F) Pressure: 30 psi (2 bar) @ 25°C, derated @ 1.667 psi (0.115 bar) per °C above 25°C Enclosure Rating: NEMA 6 (IP67), NEMA 4X (IP65) optional Enclosure Material: PC/ABS FR Transducer Material: PVDF Cable Jacket Material: PP Cable: 3-conductor, shielded 3 m (10') Conduit Entrance: Dual, ½ NPT on NEMA 4 (IP65) version Process Mount: LVU104/109: 1 NPT or 1" G LVU116/126: 2 NPT or 2" G Mounting Gasket: FKM Classification: General purpose CE compliance
注: Comes complete with operator's manual and 3 m (10') cable.
For NEMA 4X (IP65) rated enclosure, add suffix "NEMA4" to the model number, add $55 to the price. Cable is not included with "-NEMA4" models.